Nafion-coated bismuth film and Nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry

被引:25
作者
Cao, Grace X.
Jimenez, Omar
Zhou, Feimeng [1 ]
Xu, Maotian
机构
[1] Calif State Univ Los Angeles, Dept Chem & Biochem, Los Angeles, CA 90032 USA
[2] Cent S Univ, Coll Chem & Chem Engn, Hunan, Peoples R China
关键词
D O I
10.1016/j.jasms.2006.03.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nafion-coated bismuth film electrodes (NCBFEs) and Nation-coated mercury film electrodes (NCMFEs) were used to electrochemically preconcentrate metal analytes for subsequent analysis by inductively coupled plasma-mass spectrometry (ICP-MS). Either type of electrodes is part of a thin-layer electrochemical flow cell that is positioned upstream of microconcentric nebulizer for the ICP-MS. Performances of these electrodes were compared in terms of the analytical "figures of merit" (e.g., dynamic ranges, reproducibility, hydrodynamic stability, and elimination of matrix effects detrimental to ICP-MS). The coupled technique (ASV-ICP-MS) is found to possess a wide dynamic range (at least 4 to 5 orders of magnitude) and to be reproducible. Both electrodes are much more stable than the thin mercury film electrode (TMFE) traditionally used for ASV-ICP-MS, with the lifetime of the NCBFE exceeding 8 h. Adopting these electrodes for ASV-ICP-MS overcomes the problems associated with a TMFE, the erosion of which decreases the sample throughput, affects the analysis precision, and contaminates conventional glass nebulizers and spray chambers of the spectrometer. The medium exchange procedure inherent in ASV is successfully implemented with a two-valve flow injection system for the accumulation of trace Cd2+ into the electrode from a certified seawater sample, followed by stripping Cd into a solution that is compatible to the ICP-MS operation.
引用
收藏
页码:945 / 952
页数:8
相关论文
共 47 条
[1]   Anodic stripping voltammetry combined on-line with inductively coupled plasma-MS via a direct-injection high-efficiency nebulizer [J].
Baca, AJ ;
De la Ree, AB ;
Zhou, FM ;
Mason, AZ .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2507-2511
[2]   Quantification of metals released by metallothionein adsorbates at mercury film electrodes by electrochemical ICP-atomic emission spectrometry [J].
Baca, AJ ;
Garcia, Y ;
Briseno, AL ;
Zhou, FM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 513 (01) :25-35
[3]   Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes [J].
Banks, CE ;
Kruusma, J ;
Hyde, ME ;
Salimi, A ;
Compton, RG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (02) :277-282
[4]  
Bard A.J., 2001, Electrochemical Methods: Fundamentals and Applications, V2nd, P808
[5]   Quantification of dopant ions in polypyrrole films with electrochemical ICP-atomic emission spectrometry and comparison to electrochemical quartz crystal microbalance studies [J].
Briseno, AL ;
Baca, A ;
Zhou, QZ ;
Lai, R ;
Zhou, FM .
ANALYTICA CHIMICA ACTA, 2001, 441 (01) :123-134
[6]   Mercury film electrodes: developments, trends and potentialities for electroanalysis [J].
Economou, A ;
Fielden, PR .
ANALYST, 2003, 128 (03) :205-212
[7]   NAFION-COATED MERCURY-COATED GLASSY-CARBON ELECTRODES FOR METALS ANALYSIS AND SPECIATION [J].
GUY, RD ;
NAMARATNE, S .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1987, 65 (05) :1133-1138
[8]  
Harris D. C., 2003, QUANTITATIVE CHEM AN, pAP23
[9]   SIGNAL STABILITY OF NAFION-COATED THIN MERCURY FILM ELECTRODES FOR STRIPPING VOLTAMMETRY [J].
HOYER, B ;
JENSEN, N .
TALANTA, 1994, 41 (03) :449-453
[10]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES TO THE DIRECT DETERMINATION OF TRACE-METALS IN BODY-FLUIDS BY ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2839-2842