Biodistribution and computed tomography blood-pool imaging properties of polyethylene glycol-coated iopromide-carrying liposomes

被引:37
作者
Sachse, A
Leike, JU
Schneider, T
Wagner, SE
Rossling, GL
Krause, W
Brandl, M
机构
[1] LS PHARMAZEUT TECHNOL,INST PHARMAZEUT,FREIBURG,GERMANY
[2] INST DIAGNOST FORSCH,BERLIN,GERMANY
关键词
liposomes; iopromide; computed tomography; polyethylene glycol; biodistribution; blood-pool agent;
D O I
10.1097/00004424-199701000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONAL AND OBJECTIVES. Surface-modified contrast-carrying liposomes potentially are useful as computed tomography (CT) blood-pool agents. The biodistribution and CT-imaging behavior of conventional as well as polyethylene glycol (PEG)-coated iopromide-carrying liposomes were tested. Two different types of PEG-ylated lipids were used to demonstrate possible differences. METHODS. Iopromide-containing liposomes were prepared by a continuous high-pressure extrusion method and subsequently PEG-ylated by simple mixing with either DSPE-PEG2000 or CHHS-PEG2000. The resulting liposomes were investigated in rats (biodistribution) and rabbits (imaging). RESULTS. Surface modification with CHHS-PEG consistently resulted in less effective stabilization of liposomes in the blood than with DSPE-PEG. In the biodistribution study, no significant differences in blood concentration could be found 1 hour after injection between the different formulations at a dose of 250 mg total iodine/kg body weight (approximately 500 mg lipid/kg). At this dose, the unmodified as well as the DSPE-PEG liposomes displayed prolonged blood circulation with CT density differences above 70 Hounsfield units (aorta) for up to 20 minutes (n = 1). CONCLUSIONS. DSPE-PEG-coated and unmodified liposomes proved to be useful for CT blood-pool imaging displaying favorable imaging properties. Future studies will have to demonstrate whether PEG-ylation offers diagnostic or toxicologic advantages over conventional vesicles in this indication.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 20 条
[1]   THE USE OF GLYCOLIPIDS AND HYDROPHILIC POLYMERS IN AVOIDING RAPID UPTAKE OF LIPOSOMES BY THE MONONUCLEAR PHAGOCYTE SYSTEM [J].
ALLEN, TM .
ADVANCED DRUG DELIVERY REVIEWS, 1994, 13 (03) :285-309
[2]   LIPOSOMES CONTAINING SYNTHETIC LIPID DERIVATIVES OF POLY(ETHYLENE GLYCOL) SHOW PROLONGED CIRCULATION HALF-LIVES INVIVO [J].
ALLEN, TM ;
HANSEN, C ;
MARTIN, F ;
REDEMANN, C ;
YAUYOUNG, A .
BIOCHIMICA ET BIOPHYSICA ACTA, 1991, 1066 (01) :29-36
[3]   LONG-CIRCULATING BLOOD-POOL IMAGING AGENTS [J].
BOGDANOV, A ;
WEISSLEDER, R ;
BRADY, TJ .
ADVANCED DRUG DELIVERY REVIEWS, 1995, 16 (2-3) :335-348
[4]  
Fonseca MJ, 1996, BBA-BIOMEMBRANES, V1279, P259
[5]  
Gazelle G S, 1994, Acad Radiol, V1, P373
[6]   EFFECT OF LIPOSOME SIZE ON THE CIRCULATION TIME AND INTRAORGAN DISTRIBUTION OF AMPHIPATHIC POLY(ETHYLENE GLYCOL)-CONTAINING LIPOSOMES [J].
LITZINGER, DC ;
BUITING, AMJ ;
VANROOIJEN, N ;
HUANG, L .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1994, 1190 (01) :99-107
[7]   IODINATED POLYMER AS BLOOD POOL CONTRAST AGENT - COMPUTED-TOMOGRAPHY EVALUATION IN RABBITS [J].
REVEL, D ;
CHAMBON, C ;
HAVARD, P ;
DANDIS, G ;
CANET, E ;
COROT, C ;
AMIEL, M .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S57-S59
[8]  
SACHSE A, 1993, INVEST RADIOL, V28, P838
[9]   GENERATION OF CONTRAST-CARRYING LIPOSOMES OF DEFINED SIZE WITH A NEW CONTINUOUS HIGH-PRESSURE EXTRUSION METHOD [J].
SCHNEIDER, T ;
SACHSE, A ;
ROSSLING, G ;
BRANDL, M .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1995, 117 (01) :1-12
[10]   Surface modification of continuously extruded contrast-carrying liposomes: Effect on their physical properties [J].
Schneider, T ;
Sachse, A ;
Leike, J ;
Rossling, G ;
Schmidtgen, M ;
Drechsler, M ;
Brandl, M .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 132 (1-2) :9-21