Direct hemoglobin measurement on a centrifugal microfluidic platform for point-of-care diagnostics

被引:50
作者
Steigert, J.
Grumann, M.
Dube, M.
Streule, W.
Riegger, L.
Brenner, T.
Koltay, P.
Mittmann, K.
Zengerle, R.
Ducree, J.
机构
[1] Univ Freiburg, Dept Microsyst Engn, Lab MEMS Applicat, D-79110 Freiburg, Germany
[2] Univ Appl Sci, EUREGIO Biotech Ctr, D-48565 Steinfurt, Germany
[3] HSG IMIT, D-79110 Villingen, Germany
关键词
hemoglobin; colorimetric assay; centrifugal microfluidics; point-of-care; human whole blood;
D O I
10.1016/j.sna.2006.01.031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a novel concept to determine relevant biochemical markers for applications in the field of emergency diagnostics. Our modular setup comprises a disposable polymer disk which hosts microfluidic structures and optical beam-guidance elements. The beam of a standard laser is guided by total internal reflection (TIR) at V-grooved retro reflectors which are monolithically integrated on a "lab-on-a-disk". This way, the optical path length through the commonly flat detection cell and thus the sensitivity of colorimetric assays is massively enhanced compared to direct (perpendicular) beam incidence. The reusable analyzer compactly incorporates a standard drive to spin the disk, a dispensing unit, a low-cost laser, and a spectrophotometer serving as flexible detector for different assay formats. The competitive performance of the setup was proven by the rapid and accurate determination of the concentration of hemoglobin (Hb) in human whole blood. Outstanding features are a high degree of linearity (R-2 = 0.993) between the optical signal and the Hb, a good reproducibility of CV = 2.9%, and a time-to-result of 100 s, only. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 233
页数:6
相关论文
共 28 条
[1]  
*AB INC, PICC
[2]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[3]   Fluorescent ion-selective optode membranes incorporated onto a centrifugal microfluidics platform [J].
Badr, IHA ;
Johnson, RD ;
Madou, MJ ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2002, 74 (21) :5569-5575
[4]   Airbone particles dynamics: towards a theoretical approach [J].
Brenig, L ;
Offer, Z .
ENVIRONMENTAL MODELING & ASSESSMENT, 2001, 6 (01) :1-5
[5]  
*DIAGL GMBH, HB342
[6]  
Ducree J., 2004, FLOWMAP MICROFLUIDIC
[7]   Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays [J].
Duffy, DC ;
Gillis, HL ;
Lin, J ;
Sheppard, NF ;
Kellogg, GJ .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4669-4678
[8]  
Ekstrand G, 2000, MESA MG, P311
[9]   Batch-mode mixing on centrifugal microfluidic platforms [J].
Grumann, M ;
Geipel, A ;
Riegger, L ;
Zengerle, R ;
Ducrée, J .
LAB ON A CHIP, 2005, 5 (05) :560-565
[10]  
GRUMANN M, 2005, P TRANSD 2005 C, V2, P114