A newly developed peripheral anterior chamber depth analysis system: principle, accuracy, and reproducibility

被引:28
作者
Kashiwagi, K [1 ]
Kashiwagi, F [1 ]
Toda, Y [1 ]
Osada, K [1 ]
Tsumura, T [1 ]
Tsukahara, S [1 ]
机构
[1] Univ Yamanashi, Fac Med, Dept Ophthalmol, Yamanashi 4093898, Japan
关键词
D O I
10.1136/bjo.2003.036699
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Aim: To develop a new, non-contact system for measuring anterior chamber depth (ACD) quantitatively, and to investigate its accuracy as well as interobserver and intraobserver reproducibility. Methods: The system scanned the ACD from the optical axis to the limbus in approximately 0.5 second and took 21 consecutive slit lamp images at 0.4 mm intervals. A computer installed program automatically evaluated the ACD, central corneal thickness (CT), and corneal radius of curvature (CRC) instantly. A dummy eye was used for investigating measurement accuracy. The effects of CT and CRC on the measurement results were examined using a computer simulation model to minimise measurement errors. Three examiners measured the ACD in 10 normal eyes, and interobserver and intraobserver reproducibility was analysed. Results: The ACD values measured by this system were very similar to theoretical values. Increase of CRC and decrease in CT decreased ACD and vice versa. Data calibration using evaluated CT and CRC successfully reduced measurement errors. Intraobserver and interobserver variations were small. Their coefficient variation values were 7.4% (SD 2.3%) and 6.7% (0.7%), and these values tended to increase along the distance from the optical axis. Conclusion: The current system can measure ACD with high accuracy as well as high intraobserver and interobserver reproducibility. It has potential use in measuring ACD quantitatively and screening subjects with narrow angle.
引用
收藏
页码:1030 / 1035
页数:6
相关论文
共 15 条
[1]
BOKER T, 1995, OPHTHALMIC RES, V27, P104
[2]
Bosem M E, 1992, J Glaucoma, V1, P254, DOI 10.1097/00061198-199201040-00008
[3]
A proposed simple method for measurement in the anterior chamber angle -: Biometric gonioscopy [J].
Congdon, NG ;
Spaeth, GL ;
Augsburger, J ;
Klancnik, J ;
Patel, K ;
Hunter, DG .
OPHTHALMOLOGY, 1999, 106 (11) :2161-2167
[4]
Rotating slit image camera TOPCON SL 45 - New developments for simultaneous image acquisition by photographic and CCD-assisted on-line documentation [J].
Dragomirescu, V ;
Hockwin, O .
OPHTHALMIC RESEARCH, 1996, 28 :102-108
[5]
A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes [J].
Gazzard, G ;
Friedman, DS ;
Devereux, JG ;
Chew, P ;
Seah, SKL .
OPHTHALMOLOGY, 2003, 110 (03) :630-638
[6]
Ishikawa H, 2000, Curr Opin Ophthalmol, V11, P133, DOI 10.1097/00055735-200004000-00012
[7]
ANTERIOR-CHAMBER DEPTH MEASUREMENT USING THE SLIT-LAMP MICROSCOPE [J].
JACOBS, IH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (02) :236-238
[8]
THE EFFECT OF IRIDOTOMY ON IRIS CONTOUR [J].
JIN, JC ;
ANDERSON, DR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (03) :260-263
[9]
LEE DA, 1984, ARCH OPHTHALMOL-CHIC, V102, P46
[10]
Malacara D., 1992, OPTICAL SHOP TESTING, P455