PURPOSE: To evaluate the accuracy of autorefraction using three autorefractors comparing to subjective refraction in diagnosing refractive error in children. DESIGN: A cross-sectional study. METHODS: SETTING: Community based study. STUDY POPULATION: 117 children sampled from primary schools. PROCEDURES: All subjects underwent autorefraction using three auto refractors and subjective refraction with and without cycloplegia. MAIN OUTCOME MEASURES: Spherical power, cylindrical power, and spherical equivalence (SE). RESULTS: Without cycloplegia, the mean SE were significantly different for Retinomax K plus 2 (-1.55 diopters, SD 2.37 diopters; 95% CI -1.98 to -1.12; P < .0001) and Canon RF10 (-1.11 diopters; SD 2.61 diopters; 95% CI -1.59 to -0.64; P = .0023) compared with monocular subjective refraction (-0.80 diopters; SD 2.25 diopters; 95% CI -1.21 to -0.35). Mean SE was significantly different for Grand Seiko WR5100K (-0.79 diopters; SD 2.40 diopters; 95% CI -1.23 to -0.35; P = .0002) compared with binocular subjective refraction (-0.62 diopters; SD 2.51 diopters; 95% CI -1.07 to -0.16). With cycloplegia, there was no significant difference in mean SE between refraction methods. Sensitivity and specificity results for the diagnosis of myopia: Without cycloplegia: Retinomax K plus 2 (sensitivity 1.0, specificity 0.51); Canon RF10 (sensitivity 0.92, specificity 0.81); and Grand Seiko WR5100K (sensitivity 0.91, specificity 0.98). With cycloplegia: Retinomax K plus 2 (sensitivity 0.97, specificity 0.99); Canon RF10 (sensitivity 0.97, specificity 0.96); and Grand Seiko WR5100K (sensitivity 1.0, specificity 0.97). CONCLUSIONS: Under noncycloplegic conditions, all three autorefractors have a tendency towards minus over correction in children resulting in over diagnosis of myopia. However autorefractors were accurate under cycloplegic conditions.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 47 条
[1]
Testing young infants with the Welch Allyn SureSight non-cycloplegic autorefractor [J].
Adams, RJ ;
Dalton, SM ;
Murphy, AM ;
Hall, HL ;
Courage, ML .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2002, 22 (06) :546-551
[2]
Non-cycloplegic screening for amblyopia via refractive findings with the Nikon Retinomax hand held autorefractor in 3 year old kindergarten children [J].
Barry, JC ;
König, HH .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (10) :1179-1182
[3]
The repeatability of automated and clinician refraction [J].
Bullimore, MA ;
Fusaro, RE ;
Adams, CW .
OPTOMETRY AND VISION SCIENCE, 1998, 75 (08) :617-622
[4]
De/colonizing the exotic: Teaching "Asian women" in a US classroom [J].
Chatterjee, P .
FRONTIERS-A JOURNAL OF WOMEN STUDIES, 2000, 21 (1-2) :87-110
[5]
Refractive errors in an elderly Chinese population in Taiwan: The Shihpai eye study [J].
Cheng, CY ;
Hsu, WM ;
Liu, JH ;
Tsai, SY ;
Chou, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (11) :4630-4638
[6]
Cordonnier, 1998, Strabismus, V6, P133
[7]
Cordonnier M, 2001, Strabismus, V9, P59, DOI 10.1076/stra.9.2.59.701
[8]
Screening for abnormal levels of hyperopia in children: a non-cycloplegic method with a hand held refractor [J].
Cordonnier, M ;
Dramaix, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (11) :1260-1264
[9]
Screening for refractive errors in children: accuracy of the hand held refractor Retinomax to screen for astigmatism [J].
Cordonnier, M ;
Dramaix, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (02) :157-161
[10]
Clinical evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K autorefractor [J].
Davies, LN ;
Mallen, EAH ;
Wolffsohn, JS ;
Gilmartin, B .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (04) :320-324