ANATOMICAL INFORMATION IS NEEDED IN ULTRASOUND IMAGING OF MUSCLE TO AVOID POTENTIALLY SUBSTANTIAL ERRORS IN MEASUREMENT OF MUSCLE GEOMETRY

被引:121
作者
Benard, Menno R. [1 ,2 ]
Becher, Jules G. [2 ]
Harlaar, Jaap [2 ]
Huijing, Peter A. [1 ]
Jaspers, Richard T. [1 ]
机构
[1] Vrije Univ Amsterdam, Res Inst Move, Fac Human Movement Sci, NL-1081 BT Amsterdam, Netherlands
[2] VU Med Ctr, Res Inst Move, Dept Rehabil Med, Amsterdam, Netherlands
关键词
ultrasound imaging; probe orientation; muscle geometry; human medial gastrocnemius; HUMAN GASTROCNEMIUS-MUSCLE; HEMIPLEGIC CEREBRAL-PALSY; IN-VIVO MEASUREMENTS; SKELETAL-MUSCLE; MEDIAL GASTROCNEMIUS; SPASTIC DIPLEGIA; JOINT ANGLE; 3RD HEAD; ARCHITECTURE; CONTRACTION;
D O I
10.1002/mus.21287
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study validates two-dimensional (2D) ultrasound measurements of muscle geometry of the human medial gastrocnernius (GM) and investigates effects of probe orientation on errors in these measurements. Ultrasound scans of GM muscle belly were made both on human cadavers (n = 4) and on subjects in vivo (n = 5). For half of the cadavers, ultrasound scans obtained according to commonly applied criteria of probe orientation deviated 15 degrees from the true fascicle plane. This resulted in errors of fascicle length and fascicle angle up to 14% and 23%, respectively. Fascicle-like structures were detectable over a wide range of probe tilt and rotation angles, but they did not always represent true fascicles. Errors of measurement were either linear or quadratic functions of tilt angle. Similar results were found in vivo. Therefore, we conclude that similar errors are likely to occur for in vivo measurements. For all cadavers, at the distal end of GM, the true fascicle plane was shown to be perpendicular to the distal aponeurosis. Using transverse images of GM to detect the curvature of the deep aponeurosis at the distal end of the muscle belly is a simple strategy to help identify the fascicle plane. For subsequent longitudinal imaging, probe alignment within this-plane will help minimize measurement errors of fascicle length, fascicle angle, and muscle thickness.
引用
收藏
页码:652 / 665
页数:14
相关论文
共 39 条
[11]   DO MUSCLE-FIBER SIZE AND FIBER ANGULATION CORRELATE IN PENNATED HUMAN MUSCLES [J].
HENRIKSSONLARSEN, K ;
WRETLING, ML ;
LORENTZON, R ;
OBERG, L .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 64 (01) :68-72
[12]   CHANGES IN PENNATION WITH JOINT ANGLE AND MUSCLE TORQUE - IN-VIVO MEASUREMENTS IN HUMAN BRACHIALIS MUSCLE [J].
HERBERT, RD ;
GANDEVIA, SC .
JOURNAL OF PHYSIOLOGY-LONDON, 1995, 484 (02) :523-532
[13]   Passive mechanical properties of human gastrocnemius muscle-tendon units, muscle fascicles and tendons in vivo [J].
Hoang, P. D. ;
Herbert, R. D. ;
Todd, G. ;
Gorman, R. B. ;
Gandevia, S. C. .
JOURNAL OF EXPERIMENTAL BIOLOGY, 2007, 210 (23) :4159-4168
[14]   Measurement of muscle contraction with ultrasound imaging [J].
Hodges, PW ;
Pengel, LHM ;
Herbert, RD ;
Gandevia, SC .
MUSCLE & NERVE, 2003, 27 (06) :682-692
[15]  
HUIJING PA, 1985, ACTA ANAT, V123, P101
[16]   Nonisometric behavior of fascicles during isometric contractions of a human muscle [J].
Ito, L ;
Kawakami, Y ;
Ichinose, Y ;
Fukashiro, S ;
Fukunaga, T .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (04) :1230-1235
[17]   POPLITEAL VEIN ENTRAPMENT CAUSED BY THE 3RD HEAD OF THE GASTROCNEMIUS-MUSCLE [J].
IWAI, T ;
SATO, S ;
YAMADA, T ;
MURAOKA, Y ;
SAKURAZAWA, K ;
KINOSHITA, H ;
INOUE, Y ;
ENDO, M ;
YOSHIDA, T ;
SUZUKI, S .
BRITISH JOURNAL OF SURGERY, 1987, 74 (11) :1006-1008
[18]   MUSCLE-FIBER PENNATION ANGLES ARE GREATER IN HYPERTROPHIED THAN IN NORMAL MUSCLES [J].
KAWAKAMI, Y ;
ABE, T ;
FUKUNAGA, T .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (06) :2740-2744
[19]   Architectural and functional features of human triceps surae muscles during contraction [J].
Kawakami, Y ;
Ichinose, Y ;
Fukunaga, T .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (02) :398-404
[20]   The effect of ultrasound probe orientation on muscle architecture measurement [J].
Klimstra, Marc ;
Dowling, Jim ;
Durkin, Jennifer L. ;
MacDonald, Maureen .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2007, 17 (04) :504-514