Performance Enhancements of Mass Selective Axial Ejection from a Linear Ion Trap

被引:27
作者
Guna, Mircea [1 ]
Biesenthal, Thomas A. [1 ]
机构
[1] MDS Analyt Technol, Concord, ON L4K 4V8, Canada
关键词
SPECTROMETER;
D O I
10.1016/j.jasms.2009.02.002
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Mass selective axial ejection (MSAE) of ions from a linear ion trap (LIT) takes advantage of the rf fringing fields at the end of the linear quadrupole to convert radial ion excitation into axial ejection. Tons gain radial amplitude via a mass selective resonance excitation process and are ejected axially over an electrostatic DC barrier. The extraction efficiency and resolution are determined by the length and shape of the extraction region in the vicinity of the exit aperture. In the work presented here, axial DC fields, created by auxiliary electrodes, were used to modify the shape of the trapping electrostatic fields along the quadrupole axis and to increase the density of the ions in the extraction region. Better confinement and ion cloud coherence increased the extraction efficiency and the spectral resolution. As a result, extraction efficiency can be increased by up to one order of magnitude at fast scan rates, i.e., 10 and 20 kTh/s, and a factor of 2-3 at the slower scan speed of I kTh/s. The length of the extraction region was also modified by application of a portion of the drive rf voltage to the end lens of the LIT. A comparison of the MSAE spectra at different scan rates and rf levels showed that extraction efficiencies increase at scan rates of 10 kTh/s or higher, with associated improvements in mass spectral peak widths. (J Am Soc Mass Spectrom 2009, 20, 1132-1140) (C) 2009 American Society for Mass Spectrometry
引用
收藏
页码:1132 / 1140
页数:9
相关论文
共 10 条
[1]
FRENCH AP, VIBRATIONS WAVES, P189
[2]
A new linear ion trap mass spectrometer [J].
Hager, JW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) :512-526
[3]
HAGER JW, 2006, Patent No. 7019290
[4]
Mass selective ejection by axial resonant excitation from a linear ion trap [J].
Hashimoto, Y ;
Hasegawa, H ;
Baba, T ;
Waki, I .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (05) :685-690
[5]
Lonchy F.R., U.S. Patent, Patent No. [6,909,089, 6909089]
[6]
Mass selective axial ion ejection from a linear quadrupole ion trap [J].
Londry, FA ;
Hager, JW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) :1130-1147
[7]
LONDRY FA, 2002, P 50 ASMS C ORL FL J
[8]
LONDRY FA, UNPUB
[9]
MARCH RE, 2009, PRACTICAL A IN PRESS, pCH12
[10]
A two-dimensional quadrupole ion trap mass spectrometer [J].
Schwartz, JC ;
Senko, MW ;
Syka, JEP .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (06) :659-669