Microvascular behavior and effects of Sonazoid microbubbles in the cremaster muscle of rats after local administration

被引:8
作者
Braide, Magnus
Rasmussen, Henrik
Albrektsson, Ann
Bagge, Ulf
机构
[1] GE Healthcare AS, Res & Dev, N-0401 Oslo, Norway
[2] Univ Gothenburg, Dept Anat & Cell Biol, Gothenburg, Sweden
关键词
capillary; fluorescein isothiocyanate; intra-arterial; Sonazoid; ultrasonographic contrast agent;
D O I
10.7863/jum.2006.25.7.883
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The purpose of this study was to observe Sonazoid perfluorobutane microbubbles (GE Healthcare, Amersham, Buckinghamshire, England) in and their effects on the cremaster capillary microcirculation of rats. Methods. Sonazoid (0.3 x 10(9) microbubbles in 0.5 mL) was observed by intravital microscopy in the cremaster muscle after retrograde administration into the femoral artery of 6 animals. Microbubble and microvessel diameters and blood flow velocities and the overall mean and 14 SD of the 1-minute volume flow through the microscopic field were calculated from the 2 to 4 capillaries observed in the field of each animal. Fluorescein isothiocyanate-dextran leakage was used to assess extravasation after microbubble passage. Results. A total of 331 bubbles of 2.4 to 3.1 mu m in median diameter were observed in 6 animals. Four bubbles (3.5-7.0 mu m) and a cluster of 4 bubbles (nominal diameter, 5.6 mu m) were plugging the observed capillaries for 18, 16, 7, 3, and 9 seconds, respectively, before they were released and capillary flow normalized. No microbubble size changes, damming, or coalescence of bubbles and no changes in microvessel diameter or microvascular blood A flow velocities, volume flow, or perfusion heterogeneity occurred during or after the passage of the Sonazoid suspension or the vehicle. No fluorescein isothiocyanate-dextran leakage was observed. Conclusions. The passage of Sonazoid bubbles at concentrations higher than those expected after intravenous administration of the Sonazoid did not durably impair microvascular perfusion, structural integrity, or macromolecular retention in the rat cremaster muscle. The duration of discrete capillary obstructions was short and in all cases comparable with that of naturally occurring leukocyte plugging.
引用
收藏
页码:883 / 890
页数:8
相关论文
共 16 条
[1]   OPEN CREMASTER MUSCLE PREPARATION FOR STUDY OF BLOOD-VESSELS BY IN-VIVO MICROSCOPY [J].
BAEZ, S .
MICROVASCULAR RESEARCH, 1973, 5 (03) :384-394
[2]  
Bagge U, 1977, ADV MICROCIRCULAT, V7, P1
[3]  
Becher H, 2000, HDB CONTRAST ECHOCAR, P1
[4]   PHYSIOLOGICAL-PARAMETERS IN LABORATORY-ANIMALS AND HUMANS [J].
DAVIES, B ;
MORRIS, T .
PHARMACEUTICAL RESEARCH, 1993, 10 (07) :1093-1095
[5]   Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent [J].
Fisher, NG ;
Christiansen, JP ;
Leong-Poi, H ;
Jayaweera, AR ;
Lindner, JR ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) :530-537
[6]   Influence of microbubble surface charge on capillary transit and myocardial contrast enhancement [J].
Fisher, NG ;
Christiansen, JP ;
Klibanov, A ;
Taylor, RP ;
Kaul, S ;
Lindner, JR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (04) :811-819
[7]  
Fowlkes JB, 2000, J ULTRAS MED, V19, P120
[8]   Detection of an occult hepatocellular carcinoma using ultrasound with liver-specific microbubbles [J].
Harvey, Christopher J. ;
Lim, Adrian K. P. ;
Blomley, Martin J. K. ;
Taylor-Robinson, Simon D. ;
Gedroyc, Wladyslaw M. W. ;
Cosgrove, David O. .
EUROPEAN RADIOLOGY, 2002, 12 (Suppl 3) :S70-S73
[9]  
Jain N.C., 1986, SCHALMS VET HEMATOLO, P274
[10]   Microvascular rheology of definity microbubbles after intra-arterial and intravenous administration [J].
Lindner, JR ;
Song, J ;
Jayaweera, AR ;
Sklenar, J ;
Kaul, S .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (05) :396-403