Site-specific specimen preparation by focused ion beam milling for transmission electron microscopy of metal matrix composites

被引:29
作者
Gasser, P
Klotz, UE
Khalid, FA
Beffort, O
机构
[1] Swiss Fed Inst Mat Testing & Res, EMPA, CH-8600 Dubendorf, Switzerland
[2] Gulam Ishaq Khan Inst Engn Sci & Technol, Fac Met & Mat Engn, Topi, NW Frontier Pro, Pakistan
[3] Swiss Fed Inst Mat Testing & Res, EMPA, CH-3602 Thun, Switzerland
关键词
focused ion beam (FIB); transmission electron microscopy (TEM); aluminum; diamond; microstructure; interface;
D O I
10.1017/S1431927604040413
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work describes the application and usefulness of the focused ion beam (FIB) technique for the preparation of transmission electron microscopy (TEM) samples from metal matrix composite materials. Results on an Al/diamond composite, manufactured by the squeeze casting infiltration process, were chosen for demonstration. It is almost impossible to prepare TEM specimens of this material by any other conventional method owing to the presence of highly inhomogeneous phases and reinforcement diamond particles. The present article gives a detailed account of the salient features of the FIB technique and its operation. One of the big advantages is the possibility to prepare site-specific TEM specimens with high spatial resolution. The artifacts occurring during the specimen preparation, for example, Ga-ion implantation, curtain effects, amorphous layers, bending of the lamella, or different milling behaviors of the materials have been discussed. Furthermore, TEM examination of the specimens prepared revealed an ultrafine amorphous layer of graphite formed at the interface between the Al and diamond particles that may affect the interfacial properties of the composite materials. This may not have been feasible without the successful application of the FIB technique for production of good quality site-specific TEM specimens.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 11 条
[1]  
ANDERSON R, 2002, P 15 INT C EL MICR O, P253
[2]  
ENGELMANN HJ, 2002, P 15 INT C EL MICR O, P257
[3]   A review of focused ion beam milling techniques for TEM specimen preparation [J].
Giannuzzi, LA ;
Stevie, FA .
MICRON, 1999, 30 (03) :197-204
[4]  
Giannuzzi LA, 1998, MICROSC RES TECHNIQ, V41, P285, DOI 10.1002/(SICI)1097-0029(19980515)41:4<285::AID-JEMT1>3.0.CO
[5]  
2-Q
[6]   Study of microstructure and interfaces in an aluminium-C60 composite material [J].
Khalid, FA ;
Beffort, O ;
Klotz, UE ;
Keller, BA ;
Gasser, P ;
Vaucher, S .
ACTA MATERIALIA, 2003, 51 (15) :4575-4582
[7]   Focused ion beam sample preparation of continuous fibre-reinforced ceramic composite specimens for transmission electron microscopy [J].
Kim, S.T. ;
Dravid, V.P. .
2000, Blackwell Publishing Ltd. (198)
[8]  
KLOTZ UE, 2002, P 15 INT C EL MICR O, P693
[9]  
LIPP S, 1998, 981 ERL, V98
[10]   Site-specific transmission electron microscope characterization of micrometer-sized particles using the focused ion beam lift-out technique [J].
Lomness, JK ;
Giannuzzi, LA ;
Hampton, MD .
MICROSCOPY AND MICROANALYSIS, 2001, 7 (05) :418-423