Determination of organochlorine pesticides in seawater using liquid-phase hollow fibre membrane microextraction and gas chromatography-mass spectrometry

被引:131
作者
Basheer, C
Lee, HK
Obbard, JP
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] Natl Univ Singapore, Trop Marine Sci Inst, Singapore 119223, Singapore
关键词
water analysis; environmental analysis; hollow-fiber membranes; extraction methods; liquid-phase microextraction; pesticides; organochlorine compounds;
D O I
10.1016/S0021-9673(02)00793-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of hollow fibre membrane microextraction in analytical chemistry has been increasing as the technique is a simple and efficient method for the extraction of trace organic compounds from environmental matrices. A simple liquid-phase microextraction technique using a hollow fibre membrane in conjunction with gas chromatography-mass spectrometry has been developed for the extraction and analysis of organochlorine pesticides (OCPs), i.e. alpha-hexachlorocyclohexane (BHC), lindane, beta-BHC, heptachlor, aldrin, dieldrin, endrin, endosulfan, p,p'-DDD, p,p'-DDT, endrin aldehyde and methoxychlor, from seawater. The technique requires minimal sample preparation time and solvent consumption, and represents a significant advantage over conventional analytical methods. Optimum extraction conditions have been evaluated with respect to sample pH, salt content and stirring rate, as well as solvent type and extraction time. A high level of detection linearity (coefficient of >0.9995, less than 14% RSD) was obtained for OCPs over a range of analyte concentrations between 5 and 100 mug l(-1), with detection limits in the parts per trillion (ppt) to sub-parts per billion range. Comparison between liquid-phase microextraction with hollow fibre membrane and US Environmental Protection Agency Method 508 showed that the novel method has comparable detection limits of between 0.013 and 0.059 mug l(-1) in seawater. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 32 条
[1]   Solid-phase microextraction and gas chromatography with mass spectrometric detection for the determination of pesticides in aqueous samples [J].
Aguilar, C ;
Peñalver, S ;
Pocurull, E ;
Borrull, F ;
Marcé, RM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 795 (01) :105-115
[2]  
[Anonymous], TRENDS ANAL CHEM
[3]   Strategies for solvent selection - A literature review [J].
Barwick, VJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (06) :293-309
[4]   INVIVO MASS-SPECTROMETRIC DETERMINATION OF ORGANIC-COMPOUNDS IN BLOOD WITH A MEMBRANE PROBE [J].
BRODBELT, JS ;
COOKS, RG ;
TOU, JC ;
KALLOS, GJ ;
DRYZGA, MD .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :454-458
[5]   DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) :2844-2848
[6]   BINDING OF DDT TO DISSOLVED HUMIC MATERIALS [J].
CARTER, CW ;
SUFFET, IH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1982, 16 (11) :735-740
[7]   Solvent microextraction of chlorinated pesticides [J].
de Jager, LS ;
Andrews, ARJ .
CHROMATOGRAPHIA, 1999, 50 (11-12) :733-738
[8]   Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC) [J].
de Jager, LS ;
Andrews, ARJ .
ANALYST, 2000, 125 (11) :1943-1948
[9]   CONTINUOUS MEASUREMENT OF DISSOLVED-GASES IN BIOCHEMICAL SYSTEMS WITH THE QUADRUPOLE MASS-SPECTROMETER [J].
DEGN, H ;
COX, RP ;
LLOYD, D .
METHODS OF BIOCHEMICAL ANALYSIS, 1985, 31 :165-194
[10]   Factors affecting the transfer of organochlorine pesticide residues to breastmilk [J].
Harris, CA ;
Woolridge, MW ;
Hay, AWM .
CHEMOSPHERE, 2001, 43 (02) :243-256