Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC)

被引:108
作者
de Jager, LS [1 ]
Andrews, ARJ [1 ]
机构
[1] Ohio Univ, Ctr Intelligent Chem Instrumentat, Dept Chem, Athens, OH 45701 USA
关键词
D O I
10.1039/b004350h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL(-1) were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL(-1). Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.
引用
收藏
页码:1943 / 1948
页数:6
相关论文
共 17 条
[1]   ENVIRONMENTAL-PROTECTION-AGENCY AND OTHER METHODS FOR THE DETERMINATION OF PRIORITY PESTICIDES AND THEIR TRANSFORMATION PRODUCTS IN WATER [J].
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :117-143
[2]   Simultaneous determination of 60 pesticides in water using solid-phase microextraction and gas chromatography mass spectrometry [J].
BoydBoland, AA ;
Magdic, S ;
Pawliszyn, JB .
ANALYST, 1996, 121 (07) :929-937
[3]   BINDING OF DDT TO DISSOLVED HUMIC MATERIALS [J].
CARTER, CW ;
SUFFET, IH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1982, 16 (11) :735-740
[4]   Solvent microextraction of chlorinated pesticides [J].
de Jager, LS ;
Andrews, ARJ .
CHROMATOGRAPHIA, 1999, 50 (11-12) :733-738
[5]  
DESTY DH, 1965, ADV CHROMATOGR, V1, P199
[6]   Solid phase microextraction with temperature-programmed desorption for the analysis of iodination disinfection byproducts [J].
Frazey, PA ;
Barkley, RM ;
Sievers, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :638-644
[7]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[8]   New fast screening method for organochlorine pesticides in water by using solid-phase microextraction with fast gas chromatography and a pulsed-discharge electron capture detector [J].
Jackson, GP ;
Andrews, ARJ .
ANALYST, 1998, 123 (05) :1085-1090
[9]   Solvent microextraction into a single drop [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2236-2240
[10]   Mass transfer characteristics of solvent extraction into a single drop at the tip of a syringe needle [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :235-239