Noninvasive assessment of portomesenteric venous thrombosis: Current concepts and imaging strategies

被引:46
作者
Bradbury, MS [1 ]
Kavanagh, PV [1 ]
Chen, MY [1 ]
Weber, TM [1 ]
Bechtold, RE [1 ]
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Radiol, Winston Salem, NC 27157 USA
关键词
portomesenteric venous thrombosis; noninvasive imaging;
D O I
10.1097/00004728-200205000-00014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rapid, noninvasive imaging strategies, especially multidetector spiral CT and CT angiography (CTA) as well as gadolinium-enhanced MR angiography (MRA), have facilitated early diagnosis of splanchnic venous thrombosis, a potentially lethal cause of intestinal ischemia. Single breath-hold volumetric acquisitions permit superior temporal and contrast resolution while eliminating motion artifact and suppressing respiratory misregistration. Increased spatial resolution is aided by thinner slice collimation. These cross-sectional imaging techniques are becoming a preferred noninvasive alternative to conventional selective mesenteric angiography with delayed imaging for venous evaluation and should be considered the primary diagnostic modalities for evaluating patients with high clinical suspicion of nonsurgical mesenteric ischemia.
引用
收藏
页码:392 / 404
页数:13
相关论文
共 87 条
[1]  
Baden JG, 1999, JMRI-J MAGN RESON IM, V10, P369, DOI 10.1002/(SICI)1522-2586(199909)10:3<369::AID-JMRI19>3.0.CO
[2]  
2-X
[3]   CENTRIC PHASE-ENCODING ORDER IN 3-DIMENSIONAL MP-RAGE SEQUENCES - APPLICATION TO ABDOMINAL IMAGING [J].
BAMPTON, AEH ;
RIEDERER, SJ ;
KORIN, HW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :327-334
[4]   SPIRAL CT ANGIOGRAPHY - AN ALTERNATIVE TO CONVENTIONAL ANGIOGRAPHY [J].
BLUEMKE, DA ;
CHAMBERS, TP .
RADIOLOGY, 1995, 195 (02) :317-319
[5]  
BRADBURY MS, IN PRESS RADIOGRAPHI
[6]   Spiral CT angiography of the abdomen and pelvis: Interventional applications [J].
Brink, JA .
ABDOMINAL IMAGING, 1997, 22 (04) :365-372
[7]  
BRINK JA, 1995, RADIOL CLIN N AM, V33, P825
[8]   TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS [J].
BRINK, JA ;
LIM, JT ;
WANG, G ;
HEIKEN, JP ;
DEYOE, LA ;
VANNIER, MW .
RADIOLOGY, 1995, 194 (01) :157-163
[9]  
BRINK JA, 1995, HELICAL SPIRAL CT PR, P1
[10]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593