Assessment of pupil size under different light intensities using the Procyon pupillometer

被引:24
作者
Cheng, Arthur C. K. [1 ]
Rao, Srinivas K. [1 ]
Cheng, Lulu L. [1 ]
Lam, Dennis S. C. [1 ]
机构
[1] Chinese Univ Hong Kong, Univ Eye Ctr, Dept Ophthalmol & Visual Sci, Hong Kong Eye Hosp, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1016/j.jcrs.2006.02.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the relationship between pupil size and light intensity using the Procyon pupillometer. SETTING: University based clinic. METHODS: In this retrospective study, 20 consecutive patients had pupil size assessment with the Procyon pupillometer under 3 different light conclitions-4, 0.4, and 0.04 lux. Correlation was established using the log unit of the light intensity and pupil size. RESULTS: The correlation coefficient for the association between pupil size and log unit of light intensity in all eyes was significant (P<.001). The mean correlation coefficient for the association between pupil size and log unit of light intensity in all patients was 0.968 +/- 0.089 (SD) in the right eye and 0.970 +/- 0.031 in the left eye. CONCLUSION: The linear relationship between the pupil size and the log unit of the light intensity showed a tight correlation in all cases. These results can be useful in the comparing pupil size with pupillometers that work under different light conditions.
引用
收藏
页码:1015 / 1017
页数:3
相关论文
共 8 条
[1]   Preoperative measurement of scotopic pupil dilation using an office pupillometer [J].
Colvard, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (12) :1594-1597
[2]   Night vision disturbances after corneal refractive surgery [J].
Fan-Paul, NI ;
Li, J ;
Miller, JS ;
Florakis, GJ .
SURVEY OF OPHTHALMOLOGY, 2002, 47 (06) :533-546
[3]   Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter [J].
Kohnen, T ;
Terzi, E ;
Buhren, J ;
Kohnen, EM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) :112-117
[4]  
LOEWENFELD I, 1999, PUPIL ANATOMY PHYS 2, V1
[5]   Night vision disturbance [J].
Rosen, ES .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02) :247-249
[6]  
Salz JJ, 2004, OPHTHALMOLOGY, V111, P1620, DOI 10.1016/j.ophtha.2004.05.007
[7]   Scotopic measurement of normal pupils: Colvard versus video vision analyzer infrared pupillometer [J].
Schnitzler, EM ;
Baumeister, M ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (06) :859-866
[8]  
Wachler BSB, 1999, OPHTHALMOLOGY, V106, P319