Long-term followup after mobile-bearing total knee replacement

被引:133
作者
Buechel, FF [1 ]
机构
[1] Univ Med & Dent New Jersey, New Jersey Med Sch, Dept Orthopaed Surg, Newark, NJ 07103 USA
关键词
D O I
10.1097/01.blo.0000036529.46246.88
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Clinical, radiographic, lanalyses and survivorship were done on the initial cementless series of 309 posterior cruciate-retaining meniscal-bearing and rotating-platform New Jersey LCS(R) total knee replacements followed up for 10 to 20 years (mean, 12.4 years). Clinical results in patients surviving at least 10 years using a strict knee scoring scale were similar for posterior cruciate ligament-retaining and posterior cruciate ligament-sacrificing designs. Good to excellent results were seen in 97.9% of primary posterior cruciate-retaining-bearing prostheses and in 97.9% of primary rotating-platform prostheses. Radiographic analysis of minimum 10-year followup radiographs showed generally stable fixation of all components with gross migration seen in one tibial component (0.6%) in a patient with a failed high tibial osteotomy. Significant osteolysis was present requiring bearing exchange and bone grating in three patients with cementless rotating-platform prostheses (1.8%) who had multiple knee surgeries at an average of 10.2 years from the index surgery. Survivorship of the primary cementless posterior cruciate-retaining meniscal-bearing prostheses with an end point of revision for any mechanical reason was 97.4% at 10 years and 83% at 16 years; using an end point of a poor clinical knee score, the survivorship was 98.9% at 10 and 16 years, respectively. Survivorship of the primary cementless rotating-platform prostheses with end points of revision for any mechanical reason or a poor clinical knee score was 98.3% survivorship at 10 and 18 years, respectively. In the current study, no cementless rotating-bearing patella loosened, fractured, or dissociated in patients without prior knee surgery although one cementless rotating-bearing patella (0.6%) in a patient who had multiple knee surgeries wore through the inferior marker wire after 10.8 years, causing metallosis that required revision.
引用
收藏
页码:40 / 50
页数:11
相关论文
共 16 条
[1]
BUECHEL FF, 1991, CLIN ORTHOP RELAT R, P190
[2]
BUECHEL FF, 1989, ORTHOP CLIN N AM, V20, P147
[3]
BUECHEL FF, 2000, ORTHOPAEDIC KNOWLEDG, V2, P313
[4]
BUECHEL FF, 1994, KNEE, P1157
[5]
Buechel FF, 1982, ORTHOP REV, V11, P97
[6]
Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[7]
Mobile-bearing knee replacement - Concepts and results [J].
Callaghan, JJ ;
Insall, JN ;
Greenwald, AS ;
Dennis, DA ;
Komistek, RD ;
Murray, DW ;
Bourne, RB ;
Rorabeck, CH ;
Dorr, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (07) :1020-1041
[8]
The AGC total knee prosthesis at average 11 years [J].
Emerson, RH ;
Higgins, LL ;
Head, WC .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :418-423
[9]
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[10]
GIL GS, 1999, CLIN ORTHOP RELAT R, V367, P210