Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip

被引:97
作者
Kim, Yeon Seok [1 ]
Niazi, Javed H. [1 ]
Gu, Man Bock [1 ]
机构
[1] Korea Univ, Sch Life Sci & Biotechnol, Seoul 136701, South Korea
关键词
Aptamer; Electrochemical detection; Oxytetracycline; Interdigitated array electrode; PERFORMANCE LIQUID-CHROMATOGRAPHY; SMALL MOLECULES; LABEL-FREE; TETRACYCLINE; ANTIBIOTICS; REAGENTLESS; BIOSENSORS; SELECTION; SENSORS; BINDING;
D O I
10.1016/j.aca.2008.12.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensing system for oxytetracycline (OTC) detection was developed using ssDNA aptamer immobilized on gold interdigitated array (IDA) electrode chip. A highly specific ssDNA aptamer that bind to OTC with high affinity was employed to discriminate other tetracyclines (TCs), such as doxycycline (DOX) and tetracycline JET). The immobilized thiol-modified aptamer on gold electrode chip served as a biorecognition element for the target molecules and the electrochemical signals generated from interactions between the aptamers and the target molecules was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV). The current decrease due to the interference of bound OTC, DOX or TET was analyzed with the electron flow produced by a redox reaction between ferro- and ferricyanide. The specificity of developed EC-biosensor for OTC was highly distinguishable from the structurally similar antibiotics (DOX and TET). The dynamic range was determined to be 1-100 nM of OTC concentration in semi-logarithmic coordinates. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:250 / 254
页数:5
相关论文
共 31 条
[1]   Artificial control of gene expression in mammalian cells by modulating RNA interference through aptamer-small molecule interaction [J].
An, CI ;
Trinh, VB ;
Yokobayashi, Y .
RNA, 2006, 12 (05) :710-716
[2]  
Baker BR, 2006, J AM CHEM SOC, V128, P3138, DOI 10.1021/ja056957p
[3]   DETERMINATION OF OXYTETRACYCLINE IN FISH BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BJORKLUND, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 432 :381-387
[4]   Fast and robust simultaneous determination of three veterinary antibiotics in groundwater and surface water using a tandem solid-phase extraction with high-performance liquid chromatography-UV detection [J].
Blackwell, PA ;
Lützhoft, HCH ;
Ma, HP ;
Halling-Sorensen, B ;
Boxall, ABA ;
Kay, P .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :111-117
[5]  
De Wasch K, 1998, ANALYST, V123, P2737, DOI 10.1039/a804909b
[6]   Small-molecule screening made simple for a difficult target with a signaling nucleic acid aptamer that reports on deaminase activity [J].
Elowe, Nadine H. ;
Nutiu, Razvan ;
Allah-Hassani, Abdellah ;
Cechetto, Jonathan D. ;
Hughes, Donald W. ;
Li, Yingfu ;
Brown, Eric A. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (34) :5648-5652
[7]   Oligonucleotide aptamers that recognize small molecules [J].
Famulok, M .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 1999, 9 (03) :324-329
[8]  
Fukusho S, 2000, Nucleic Acids Symp Ser, P187
[9]   Novel electrochemical sensor system for protein using the aptamers in sandwich manner [J].
Ikebukuro, K ;
Kiyohara, C ;
Sode, K .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2168-2172
[10]  
Jayasena SD, 1999, CLIN CHEM, V45, P1628