Characterization of a commercial gas chromatography-flame ionization detection system for the in situ determination of C5-C10 hydrocarbons in ambient air

被引:25
作者
Konrad, S [1 ]
Volz-Thomas, A [1 ]
机构
[1] Forschungszentrum Julich, Inst Chem Belasteten Atmosphare ICG2, D-52425 Julich, Germany
关键词
air analysis; environmental analysis; volatile organic compounds; hydrocarbons;
D O I
10.1016/S0021-9673(00)00302-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A commercial automated gas chromatograph with preconcentration on solid adsorbents (AirmoVoc HC1010) was coupled with a mass spectrometer in parallel with the flame ionization detection (FID) system and characterized for its suitability for quasi continuous measurements of atmospheric hydrocarbons (HCs) with a time resolution of 20 min. Of the 50 identified HCs in the range C(5)-C(10), 15 elute in isolated peaks and 20 in groups of two or more HCs. The remaining 15 HCs suffer from coelution by oxygenated and halogenated compounds. Procedures to minimize and quantify the blanks and the memory from the adsorbents are described. Calibration was based on a custom-made diffusion source. The accuracy of this calibration (+/-10%, 2 sigma) was verified by analysis of a certified 70-component standard (average deviation: -4.3+/-2%). During a field experiment in Summer 1998, the HC1010 system was compared with a custom-made GC system with cryogenic preconcentration and much better separation properties but lower time resolution. In ambient air, good agreement (2 sigma deviation <14% or 10 ppt) was found for HCs and groups of HCs that are free from coelution with oxygenated compounds, whereas large discrepancies (in some cases more than a factor of three) were found for those HCs that coelute with oxygenated compounds, as identified by MS. Analysis of the mass spectra from those peaks via specific target ions showed much better agreement with the FID system of the reference GC within 25%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 234
页数:20
相关论文
共 52 条
[1]   FLAME IONIZATION DETECTOR - FURTHER COMMENTS ON MOLECULAR BREAKDOWN AND FUNDAMENTAL GROUP RESPONSES [J].
ACKMAN, RG .
JOURNAL OF GAS CHROMATOGRAPHY, 1968, 6 (10) :497-&
[2]   FUNDAMENTAL GROUPS IN THE RESPONSE OF FLAME IONIZATION DETECTORS TO OXYGENATED ALIPHATIC HYDROCARBONS [J].
ACKMAN, RG .
JOURNAL OF GAS CHROMATOGRAPHY, 1964, 2 (06) :173-179
[3]  
APEL E, COMMUNICATION
[4]   ION FORMATION IN HYDROCARBON FLAMES [J].
BLADES, AT .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1976, 54 (18) :2919-2924
[5]   ESTIMATES OF ATMOSPHERIC HYDROXYL RADICAL CONCENTRATIONS FROM THE OBSERVED DECAY OF MANY REACTIVE HYDROCARBONS IN WELL-DEFINED URBAN PLUMES [J].
BLAKE, NJ ;
PENKETT, SA ;
CLEMITSHAW, KC ;
ANWYL, P ;
LIGHTMAN, P ;
MARSH, ARW ;
BUTCHER, G .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1993, 98 (D2) :2851-2864
[6]   THERMAL-DESORPTION EFFICIENCIES FOR DIFFERENT ADSORBATE ADSORBENT SYSTEMS TYPICALLY USED IN AIR MONITORING PROGRAMS [J].
CAO, XL ;
HEWITT, CN .
CHEMOSPHERE, 1993, 27 (05) :695-705
[7]  
CICCIOLI P, 1992, HRC-J HIGH RES CHROM, V15, P75
[8]   Instrumentation and applications of fast high-resolution capillary gas chromatography [J].
David, F ;
Gere, DR ;
Scanlan, F ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :309-319
[9]   RESPONSE FACTORS FOR GAS CHROMATOGRAPHIC ANALYSES [J].
DIETZ, WA .
JOURNAL OF GAS CHROMATOGRAPHY, 1967, 5 (02) :68-&
[10]   THE GROWTH-RATE AND DISTRIBUTION OF ATMOSPHERIC METHANE [J].
DLUGOKENCKY, EJ ;
STEELE, LP ;
LANG, PM ;
MASARIE, KA .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1994, 99 (D8) :17021-17043