Characterization of a commercial gas chromatography-flame ionization detection system for the in situ determination of C5-C10 hydrocarbons in ambient air

被引:25
作者
Konrad, S [1 ]
Volz-Thomas, A [1 ]
机构
[1] Forschungszentrum Julich, Inst Chem Belasteten Atmosphare ICG2, D-52425 Julich, Germany
关键词
air analysis; environmental analysis; volatile organic compounds; hydrocarbons;
D O I
10.1016/S0021-9673(00)00302-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A commercial automated gas chromatograph with preconcentration on solid adsorbents (AirmoVoc HC1010) was coupled with a mass spectrometer in parallel with the flame ionization detection (FID) system and characterized for its suitability for quasi continuous measurements of atmospheric hydrocarbons (HCs) with a time resolution of 20 min. Of the 50 identified HCs in the range C(5)-C(10), 15 elute in isolated peaks and 20 in groups of two or more HCs. The remaining 15 HCs suffer from coelution by oxygenated and halogenated compounds. Procedures to minimize and quantify the blanks and the memory from the adsorbents are described. Calibration was based on a custom-made diffusion source. The accuracy of this calibration (+/-10%, 2 sigma) was verified by analysis of a certified 70-component standard (average deviation: -4.3+/-2%). During a field experiment in Summer 1998, the HC1010 system was compared with a custom-made GC system with cryogenic preconcentration and much better separation properties but lower time resolution. In ambient air, good agreement (2 sigma deviation <14% or 10 ppt) was found for HCs and groups of HCs that are free from coelution with oxygenated compounds, whereas large discrepancies (in some cases more than a factor of three) were found for those HCs that coelute with oxygenated compounds, as identified by MS. Analysis of the mass spectra from those peaks via specific target ions showed much better agreement with the FID system of the reference GC within 25%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 234
页数:20
相关论文
共 52 条
[31]  
PREVOT ASH, 2000, UNPUB ATMOS ENV
[32]  
PREVOT ASH, 2000, IN PRESS ATMOS ENV
[33]   COMPARISON OF TENAX TA AND CARBOTRAP FOR SAMPLING AND ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN AIR [J].
ROTHWEILER, H ;
WAGER, PA ;
SCHLATTER, C .
ATMOSPHERIC ENVIRONMENT PART B-URBAN ATMOSPHERE, 1991, 25 (02) :231-235
[34]   PROBLEMS CONNECTED WITH THE ANALYSIS OF HALOCARBONS AND HYDROCARBONS IN THE NONURBAN ATMOSPHERE [J].
RUDOLPH, J ;
JOHNEN, FJ ;
KHEDIM, A .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1986, 27 (1-2) :97-122
[35]   THE USE OF AUTOMATED ON LINE GAS-CHROMATOGRAPHY FOR THE MONITORING OF ORGANIC TRACE GASES IN THE ATMOSPHERE AT LOW-LEVELS [J].
RUDOLPH, J ;
JOHNEN, FJ ;
KHEDIM, A ;
PILWAT, G .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (02) :143-155
[36]   MEASUREMENTS OF LIGHT ATMOSPHERIC HYDROCARBONS OVER THE ATLANTIC IN REGIONS OF LOW BIOLOGICAL-ACTIVITY [J].
RUDOLPH, J ;
JOHNEN, FJ .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1990, 95 (D12) :20583-20591
[37]   THE TROPOSPHERIC DISTRIBUTION AND BUDGET OF ETHANE [J].
RUDOLPH, J .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1995, 100 (D6) :11369-11381
[38]   Climatology of ozone, PAN, CO, and NMHC in the free troposphere over the southern north Atlantic [J].
Schmitt, R ;
VolzThomas, A .
JOURNAL OF ATMOSPHERIC CHEMISTRY, 1997, 28 (1-3) :245-262
[39]  
SCHMITZ T, 1993, THESIS U GESAMTHOCHS
[40]  
SCHMITZ T, 1997, JUL3457 FORSCH JUL