Cone-beam CT with a flat-panel imager: Noise considerations for fully 3-D computed tomography

被引:27
作者
Siewerdsen, JH [1 ]
Jaffray, DA [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING | 2000年 / 3977卷
关键词
D O I
10.1117/12.384515
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Application of flat-panel imagers (FPIs) in cone-beam computed tomography (CBCT) offers a promising new modality for fully three-dimensional (3-D) x-ray imaging. Understanding the potential performance and fundamental limitations of such technology, however, requires knowledge of the noise characteristics of the 3-D imaging system. The noise performance of a prototype flat-panel cone-beam CT (FPI-CBCT) system is investigated empirically and theoretically in terms of voxel noise, noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods for NPS analysis common in characterizing 2-D imagers are extended to the fully 3-D case, and a general framework for NPS analysis in n dimensions is presented, including the important considerations of NPS convergence and normalization within the constraints of system linearity and stationarity. Factors affecting imager noise and NPS are numerous, including exposure, number of views, image blur, additive noise, reconstruction filter, and sampling matrix. The applicability of existing theoretical descriptions of CT voxel noise is examined. A theoretical cascaded systems model that accurately predicts the 2-D noise characteristics of the FPI is extended to describe the signal and noise transfer characteristics of the fully 3-D FPI-CBCT system employing filtered back-projection. Analysis of the fully 3-D NPS reveals features of the 3-D imaging system that might otherwise be missed and shows the significant effect of 3-D noise aliasing. Furthermore, it quantifies the performance of various FPI designs in CBCT (e.g., direct and indirect detectors, and variations therein) and provides a guide for the development of high-performance FPI-CBCT systems suited to specific clinical objectives.
引用
收藏
页码:408 / 416
页数:9
相关论文
共 9 条
[1]
BARRETT H H, 1976, Computers in Biology and Medicine, V6, P307, DOI 10.1016/0010-4825(76)90068-8
[2]
A SPATIAL-FREQUENCY DEPENDENT QUANTUM ACCOUNTING DIAGRAM AND DETECTIVE QUANTUM EFFICIENCY MODEL OF SIGNAL AND NOISE-PROPAGATION IN CASCADED IMAGING-SYSTEMS [J].
CUNNINGHAM, IA ;
WESTMORE, MS ;
FENSTER, A .
MEDICAL PHYSICS, 1994, 21 (03) :417-427
[3]
DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[4]
HANSON K M, 1979, Medical Physics (Woodbury), V6, P441, DOI 10.1118/1.594534
[5]
*INT COMM RAD UN M, 1996, 54 INT COMM RAD UN M
[6]
Performance of a volumetric CT scanner based upon a flat-panel imager [J].
Jaffray, DA ;
Siewerdsen, JH ;
Drake, DG .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :204-214
[7]
THE NOISE POWER SPECTRUM OF CT IMAGES [J].
KIJEWSKI, MF ;
JUDY, PF .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (05) :565-575
[8]
DETECTIVE QUANTUM EFFICIENCY OF IMAGING-SYSTEMS WITH AMPLIFYING AND SCATTERING MECHANISMS [J].
RABBANI, M ;
SHAW, R ;
VANMETTER, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05) :895-901
[9]
Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology [J].
Siewerdsen, JH ;
Antonuk, LE ;
El-Mohri, Y ;
Yorkston, J ;
Huang, W ;
Cunningham, IA .
MEDICAL PHYSICS, 1998, 25 (05) :614-628