Quantitative characterization of differential ion suppression on liquid chromatography/atmospheric pressure ionization mass spectrometric bioanalytical methods

被引:101
作者
Avery, MJ [1 ]
机构
[1] Pfizer Inc, Global Res & Dev, Groton Labs, Groton, CT 06340 USA
关键词
D O I
10.1002/rcm.895
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Ion suppression is a known phenomenon in atmospheric pressure ionization mass spectrometry. These suppression effects have been shown to adversely affect the accuracy and precision of quantitative bioanalytical methods. This paper presents a simple procedure for determining the impact of differential ion suppression on bioanalytical methods that utilize atmospheric pressure ionization mass spectrometric (APIMS) detection. This procedure was applied to the assessment of two potential internal standards, and to determine selectivity issues for another analyte which was to be measured in multiple species. Copyright (C) 2002 John wiley sons, ltd.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 11 条
[1]
[Anonymous], 2001, Guidance for Industry-bioanalytical method validation
[2]
Beaudry F, 1998, RAPID COMMUN MASS SP, V12, P1216, DOI 10.1002/(SICI)1097-0231(19980915)12:17<1216::AID-RCM304>3.0.CO
[3]
2-O
[4]
Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[5]
Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast-gradient liquid chromatography/tandem mass spectrometry [J].
Hsieh, YS ;
Chintala, M ;
Mei, H ;
Agans, J ;
Brisson, JM ;
Ng, K ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) :2481-2487
[6]
Mechanistic investigation of ionization suppression in electrospray ionization [J].
King, R ;
Bonfiglio, R ;
Fernandez-Metzler, C ;
Miller-Stein, C ;
Olah, T .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) :942-950
[7]
Factors to consider in the development of generic bioanalytical high-performance liquid chromatographic-mass spectrometric methods to support drug discovery [J].
Law, B ;
Temesi, D .
JOURNAL OF CHROMATOGRAPHY B, 2000, 748 (01) :21-30
[8]
Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[9]
Oosterkamp AJ, 1998, J MASS SPECTROM, V33, P976, DOI 10.1002/(SICI)1096-9888(1998100)33:10<976::AID-JMS710>3.0.CO
[10]
2-7