Randomised trial of standard 2D radiotherapy (RT) versus intensity modulated radiotherapy (IMRT) in patients prescribed breast radiotherapy

被引:336
作者
Donovan, Ellen
Bleakley, Natalie
Denholm, Erica
Evans, Phil
Gothard, Lone
Hanson, Jane
Peckitt, Clare
Reise, Stephanie
Ross, Gill
Sharp, Grace
Symonds-Tayler, Richard
Tait, Diana
Yarnold, John
机构
[1] Royal Marsden Hosp, Radiotherapy Dept, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden Hosp, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Clin Trials & Stat Unit, Sutton SM2 5NG, Surrey, England
[4] Royal Marsden Hosp, Dept Radiotherapy, London, England
关键词
breast cancer; radiotherapy; intensity modulation;
D O I
10.1016/j.radonc.2006.12.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Radiation dose distributions created by two dimensional (2D) treatment planning are responsible for partial volumes receiving > 107% of the prescribed dose in a proportion of patients prescribed whole breast radiotherapy after tumour excision of early breast cancer. These may contribute to clinically significant late radiation adverse effects. Aim: To test three dimensional (3D) intensity modulated radiotherapy (IMIRT) against 2D dosimetry using standard wedge compensators in terms of late adverse effects after whole breast radiotherapy. Methods: Three hundred and six women prescribed whole breast radiotherapy after tumour excision for early stage cancer were randomised to 3D IMRT (test arm) or 2D radiotherapy delivered using standard wedge compensators (control arm). All patients were treated with 6 or 10 MV photons to a dose of 50 Gy in 25 fractions to 100% in 5 weeks followed by an electron boost to the tumour bed of 11.1 Gy in 5 fractions to 100%. The primary endpoint was change in breast appearance scored from serial photographs taken before radiotherapy and at 1, 2 and 5 years follow up. Secondary endpoints included patient self-assessments of breast discomfort, breast hardness, quality of life and physician assessments of breast induration. Analysis was by intention to treat. Results: 240 (79%) patients with 5-year photographs were available for analysis. Change in breast appearance was identified in 71/122 (58%) allocated standard 2D treatment compared to only 47/118 (40%) patients allocated 3D IMRT. The control arm patients were 1.7 times more likely to have a change in breast appearance than the IMIRT arm patients after adjustment for year of photographic assessment (95% confidence interval 1.2-2.5, p = 0.008). Significantly fewer patients in the 3D IMRT group developed palpable induration assessed clinically in the centre of the breast, pectoral fold, infra-mammary fold and at the boost site. No significant differences between treatment groups were found in patient reported breast discomfort, breast hardness or quality of life. Conclusion: This analysis suggests that minimisation of unwanted radiation dose inhomogeneity in the breast reduces late adverse effects. Incidence of change in breast appearance was statistically significantly higher in patients in the standard 2D treatment arm compared with the IMRT arm. A beneficial effect on quality of life remains to be demonstrated. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:254 / 264
页数:11
相关论文
共 32 条
[1]  
[Anonymous], 1993, PRESCR REC REP PHOT
[2]   Dosimetric improvements following 3D planning of tangential breast irradiation [J].
Aref, A ;
Thornton, D ;
Youssef, E ;
He, T ;
Tekyi-Mensah, S ;
Denton, L ;
Ezzell, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1569-1574
[3]   FRACTIONATION SENSITIVITY AND LATENCY OF TELANGIECTASIA AFTER POSTMASTECTOMY RADIOTHERAPY - A GRADED-RESPONSE ANALYSIS [J].
BENTZEN, SM ;
TURESSON, I ;
THAMES, HD .
RADIOTHERAPY AND ONCOLOGY, 1990, 18 (02) :95-106
[4]  
Coles CE, 2004, RADIOTHER ONCOL, V73, pS15
[5]   Evaluation of compensation in breast radiotherapy: A planning study using multiple static fields [J].
Donovan, EM ;
Johnson, U ;
Shentall, G ;
Evans, PM ;
Neal, AJ ;
Yarnold, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (03) :671-679
[6]   Dose-position and dose-volume histogram analysis of standard wedged and intensity modulated treatments in breast radiotherapy [J].
Donovan, EM ;
Bleackley, NJ ;
Evans, PM ;
Reise, SF ;
Yarnold, JR .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (900) :967-973
[7]   DESIGN OF COMPENSATORS FOR BREAST RADIOTHERAPY USING ELECTRONIC PORTAL IMAGING [J].
EVANS, PM ;
HANSEN, VN ;
MAYLES, WPM ;
SWINDELL, W ;
TORR, M ;
YARNOLD, JR .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :43-54
[8]   The delivery of intensity modulated radiotherapy to the breast using multiple static fields [J].
Evans, PM ;
Donovan, EM ;
Partridge, M ;
Childs, PJ ;
Convery, DJ ;
Eagle, S ;
Hansen, VN ;
Suter, BL ;
Yarnold, JR .
RADIOTHERAPY AND ONCOLOGY, 2000, 57 (01) :79-89
[9]   Practical implementation of compensators in breast radiotherapy [J].
Evans, PM ;
Donovan, EM ;
Fenton, N ;
Hansen, VN ;
Moore, I ;
Partridge, M ;
Reise, S ;
Suter, B ;
Symonds-Tayler, JRN ;
Yarnold, JR .
RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) :255-265
[10]  
EVANS PM, 1996, 4 INT WORKSH EL PORT