Image correlation algorithm for measuring lymphocyte velocity and diameter changes in contracting microlymphatics

被引:45
作者
Dixon, J. Brandon
Gashev, Anatoliy A.
Zawieja, David C.
Moore, James E., Jr.
Cote, Gerard L.
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] TAMUS Hlth Sci Ctr, Dept Syst Biol & Translat Med, Coll Med, College Stn, TX USA
关键词
lymphatics; flow; image correlation; vessel contraction; lymph velocity;
D O I
10.1007/s10439-006-9225-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Efforts have recently been made to estimate wall shear stress throughout the contractile cycle of mesenteric rat lymphatics with a high speed video microscopy system. This was prompted by reports in the literature that lymphatic pumping is related to wall shear stress. While one can estimate wall shear stress by tracking lymphocyte velocity, it is prohibitively tedious to manually track particles over a reasonable time frame for a good number of experiments. To overcome this, an image correlation method similar to digital particle imaging velocimetry was developed and tested on contracting lymphatics to measure both vessel diameter and fluid velocity. The program tracked temporal fluctuations in spatially averaged velocity with a standard error of prediction of 0.4 mm/s. From these studies we have measured velocities ranging from -2 to 4 mm/s. Diameter changes were also measured with a standard error of 7 mu m. These algorithms and techniques could be beneficial for investigating various changes in contractile behavior as a function of changes in velocity and wall shear stress.
引用
收藏
页码:387 / 396
页数:10
相关论文
共 8 条
[1]
AN ALGORITHM FOR ANGIOGRAPHIC ESTIMATION OF BLOOD-VESSEL DIAMETER [J].
CLOUGH, AV ;
KRENZ, GS ;
OWENS, M ;
ALTINAWI, A ;
DAWSON, CA ;
LINEHAN, JH .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (05) :2050-2058
[2]
Measuring microlymphatic flow using fast video microscopy -: art. no. 064016 [J].
Dixon, JB ;
Zawieja, DC ;
Gashev, AA ;
Coté, GL .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (06)
[3]
DIXON JB, 2006, IN PRESS MICROCIRCUL
[4]
Regional variations of contractile activity in isolated rat lymphatics [J].
Gashev, AA ;
Davis, MJ ;
Delp, MD ;
Zawieja, DC .
MICROCIRCULATION, 2004, 11 (06) :477-492
[5]
Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct [J].
Gashev, AA ;
Davis, MJ ;
Zawieja, DC .
JOURNAL OF PHYSIOLOGY-LONDON, 2002, 540 (03) :1023-1037
[6]
ABSOLUTE CROSS-SECTIONAL AREA MEASUREMENTS IN QUANTITATIVE CORONARY ARTERIOGRAPHY BY DUAL-ENERGY DSA [J].
MOLLOI, SY ;
ERSAHIN, A ;
ROECK, WW ;
NALCIOGLU, O .
INVESTIGATIVE RADIOLOGY, 1991, 26 (02) :119-127
[7]
Image correlation method for measuring blood flow velocity in microcirculation:: correlation 'window' simulation and in vivo image analysis [J].
Tsukada, K ;
Minamitani, H ;
Sekizuka, E ;
Oshio, C .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (04) :459-471
[8]
OPTIMAL SAMPLING INTERVAL AND EDGE-DETECTION ALGORITHM FOR MEASUREMENT OF BLOOD-VESSEL DIAMETER ON A CINEANGIOGRAM [J].
UYAMA, C ;
KITA, Y ;
MATSUSITA, S .
INVESTIGATIVE RADIOLOGY, 1993, 28 (12) :1128-1133