Comparison of different methods for the preparation of porous bone substitution materials and structural investigations by synchrotron μ-computer tomography

被引:35
作者
Tadic, D
Beckmann, F
Donath, T
Epple, M [1 ]
机构
[1] Univ Duisberg Essen, Inst Inorgan Chem, D-45117 Essen, Germany
[2] GKSS Forschungszentrum Geesthacht GmbH, Mat Res Inst, D-21494 Geesthacht, Germany
关键词
bone substitution materials; microtomography; synchrotron radiation; calcium phosphate;
D O I
10.1002/mawe.200400730
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The preparation of porous biomaterials for bone substitution is an important clinical issue in current biomedical technology because the ingrowth of bone can only occur if a suitable number of sufficiently large pores is available. Different procedures are compared here: The combined chemical-thermal treatment of bovine and human cancellous bone, the calcination of bovine cancellous bone, mechanical hole-drilling, and the extraction of porogens (in this case: salt crystals). The inner structure and the porosity of all samples were studied using high-resolution synchrotron mu-computer tomography.
引用
收藏
页码:240 / 244
页数:5
相关论文
共 19 条
[1]   New developments in attenuation and phase-contrast microtomography using synchrotron radiation with low and high photon energies [J].
Beckmann, F ;
Bonse, U ;
Biermann, T .
DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 :179-187
[2]   Physical and chemical aspects of calcium phosphates used in spinal surgery [J].
Bohner, M .
EUROPEAN SPINE JOURNAL, 2001, 10 (Suppl 2) :S114-S121
[3]   X-ray computed microtomography (mu CT) using synchrotron radiation (SR) [J].
Bonse, U ;
Busch, F .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 (1-2) :133-169
[4]  
Dorozhkin SV, 2002, ANGEW CHEM INT EDIT, V41, P3130, DOI 10.1002/1521-3773(20020902)41:17<3130::AID-ANIE3130>3.0.CO
[5]  
2-1
[6]   Assessing the accuracy of high-resolution X-ray computed tomography of primate trabecular bone by comparisons with histological sections [J].
Fajardo, RJ ;
Ryan, TM ;
Kappelman, J .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2002, 118 (01) :1-10
[7]   Three-dimensional analysis of nonhuman primate trabecular architecture using micro-computed tomography [J].
Fajardo, RJ ;
Müller, R .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2001, 115 (04) :327-336
[8]   Bone-graft substitutes: Facts, fictions, and applications [J].
Greenwald, AS ;
Boden, SD ;
Goldberg, VM ;
Khan, Y ;
Laurencin, CT ;
Rosier, RN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A :98-103
[9]   Individualised, micro CT-based finite element modelling as a tool for biomechanical analysis related to tissue engineering of bone [J].
Jaecques, SVN ;
Van Oosterwyck, H ;
Muraru, L ;
Van Cleynenbreugel, T ;
De Smet, E ;
Wevers, M ;
Naert, I ;
Vander Sloten, J .
BIOMATERIALS, 2004, 25 (09) :1683-1696
[10]  
LeGeros RZ., 1991, CALCIUM PHOSPHATES O