Preliminary test of an imaging probe for nuclear medicine using hybrid pixel detectors

被引:19
作者
Bertolucci, E
Maiorino, M
Mettivier, G
Montesi, MC
Russo, P
机构
[1] Univ Naples Federico II, Dipartimento Sci Fis, I-80126 Naples, Italy
[2] Ist Nazl Fis Nucl, I-80126 Naples, Italy
关键词
hybrid pixel detectors; gamma camera; sentinel lymph node; radiation probed; Medipix;
D O I
10.1016/S0168-9002(02)00965-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We are investigating the feasibility of an intraoperative imaging probe for lymphoscintigraphy with Tc-99m tracer, for sentinel node radioguided surgery, using the Medipix series of hybrid detectors coupled to a collimator. These detectors are pixelated semiconductor detectors bump-bonded to the Medipix I photon counting read-out chip (64 x 64 pixel, 170 pm pitch) or to the Medipix2 chip (256 x 256 pixel, 55 gm pitch), developed by the European Medipix collaboration. The pixel detector we plan to use in the final version of the probe is a semi-insulating GaAs detector or a 1-2mm thick CdZnTe detector. For the preliminary tests presented here, we used 300-mum thick silicon detectors, hybridized via bump-bonding to the Medipix I chip. We used a tungsten parallel-hole collimator (7 turn thick, matrix array of 64 x 64 100 mum circular holes with 170 mum pitch), and a 22, 60 and 122 keV point-like (I mm diameter) radioactive sources, placed at various distances from the detector. These tests were conducted in order to investigate the general feasibility of this imaging probe and its resolving power. Measurements show the high resolution but low efficiency performance of the detector-collimator set, which is able to image the 122 keV source with <1 mm FWHM resolution. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 11 条
[1]   Performance of a medical imaging system for photons in the 60-140 keV energy range [J].
Amendolia, SR ;
Bisogni, MG ;
Bottigli, U ;
Ceccopieri, A ;
Delogu, P ;
Dipasquale, G ;
Fantacci, ME ;
Maestro, P ;
Marchi, A ;
Oliva, P ;
Palmiero, R ;
Pernigotti, E ;
Rosso, V ;
Stefanini, A ;
Stumbo, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3) :422-424
[2]  
BARDELLONI G, 2000, IEEE NUCL SCI S MED
[3]  
BERTOLUCCI E, 2002, IN PRESS IEEE T NUCL, V49
[4]   Performance measurement of a new high-resolution detector system for I-131 thyroid studies [J].
Bussmann, N ;
Engels, R ;
Fuss, L ;
Kemmerling, G ;
Reinartz, R ;
Langen, KJ ;
Schelten, J ;
Ziemons, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :625-627
[5]   A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting [J].
Campbell, M ;
Heijne, EHM ;
Meddeler, G ;
Pernigotti, E ;
Snoeys, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :751-753
[6]   A tongs-like intraoperative γ-probe for specific applications in radioguided oncological surgery [J].
Dusi, W ;
Angelotti, P ;
Auricchio, N ;
Bollini, D ;
Donati, A ;
Landini, G ;
Moroni, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 455 (02) :470-475
[7]  
DUSI W, 1998, IEEE NUCL SCI S MED, P754
[8]  
LLOPART X, 2001, IEEE NUCL SCI S MED
[9]  
MACDONALD LR, 2000, IEEE NUCL SCI S MED
[10]  
PITRE S, 2000, IEEE NUCL SCI S MED