Usefulness of atrial pacing for prevention and termination of atrial tachyarrhythmias in a patient with persistent atrial fibrillation

被引:6
作者
Israel, CW [1 ]
Grönefeld, G [1 ]
Li, YG [1 ]
Hohnloser, SH [1 ]
机构
[1] JW Goethe Univ Hosp, Dept Med, Div Cardiol, D-60590 Frankfurt, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2002年 / 25卷 / 10期
关键词
atrial tachyarrhythmias; atrial fibrillation; atrial antitachycardia pacing; atrial preventive pacing; pacemaker memory functions;
D O I
10.1046/j.1460-9592.2002.01527.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrial pacing with dedicated algorithms for prevention and termination of atrial tachyarrhythmias is under clinical evaluation. A patient is described with persistent symptomatic AF. After cardioversion and implantation of a DDDRP pacemaker before planned AVN ablation, the patient was free of symptoms. Early after implant, one cardioversion of AF was necessary. Over the course of 12 months, only five episodes of atrial tachyarrhythmia occurred, all automatically pace terminated within 24 hours. Thus, selected patients with persistent AF may benefit from preventive atrial pacing since the tachyarrhythmia can organize intermittently to a degree sufficient for pace termination.
引用
收藏
页码:1527 / 1529
页数:3
相关论文
共 10 条
  • [1] Effects of High-Frequency Atrial Pacing in Atypical Atrial Flutter and Atrial Fibrillation
    Giorgberidze I.
    Saksena S.
    Mongeon L.
    Mehra R.
    Krol R.B.
    Munsif A.N.
    Mathew P.
    [J]. Journal of Interventional Cardiac Electrophysiology, 1997, 1 (2) : 111 - 123
  • [2] Prevalence, characteristics and clinical implications of regular atrial tachyarrhythmias in patients with atrial fibrillation:: Insights from a study using a new implantable device
    Israel, CW
    Ehrlich, JR
    Grönefeld, G
    Klesius, A
    Lawo, T
    Lemke, B
    Hohnloser, SH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (02) : 355 - 363
  • [3] Israel CW, 2002, ADVANCES IN THE TREATMENT OF ATRIAL TACHYARRHYTHMIAS: PACING, CARDIOVERSION, AND DEFIBRILLATION, P139
  • [4] Pace-termination and pacing for prevention of atrial tachyarrhythmias:: Results from a multicenter study with an implantable device for atrial therapy
    Israel, CW
    Hügl, B
    Unterberg, C
    Lawo, T
    Kennis, I
    Hettrick, D
    Hohnloser, SH
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (10) : 1121 - 1128
  • [5] Conflicting issues in permanent right atrial lead positioning
    Israel, CW
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1581 - 1584
  • [6] REGIONAL ENTRAINMENT OF ATRIAL-FIBRILLATION STUDIED BY HIGH-RESOLUTION MAPPING IN OPEN-CHEST DOGS
    KIRCHHOF, C
    CHORRO, F
    SCHEFFER, GJ
    BRUGADA, J
    KONINGS, K
    ZETALAKI, Z
    ALLESSIE, M
    [J]. CIRCULATION, 1993, 88 (02) : 736 - 749
  • [7] Failure of single- and multisite high-frequency atrial pacing to terminate atrial fibrillation
    Paladino, W
    Bahu, M
    Knight, BP
    Weiss, R
    Sousa, J
    Zivin, A
    Goyal, R
    Daoud, E
    Man, KC
    Strickberger, SA
    Morady, F
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (02) : 226 - 227
  • [8] What is the relationship of atrial flutter and fibrillation?
    Roithinger, FX
    Lesh, MD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (04): : 643 - 654
  • [9] Spontaneous onset of type I atrial flutter in patients
    Waldo, AL
    Cooper, TB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (03) : 707 - 712
  • [10] ATRIAL-FIBRILLATION BEGETS ATRIAL-FIBRILLATION - A STUDY IN AWAKE CHRONICALLY INSTRUMENTED GOATS
    WIJFFELS, MCEF
    KIRCHHOF, CJHJ
    DORLAND, R
    ALLESSIE, MA
    [J]. CIRCULATION, 1995, 92 (07) : 1954 - 1968