Resonators suitable for time-domain electron paramagnetic resonance spectroscopy and imaging at a radiofrequency capable of accommodating experimental animals such as mice are described. Design considerations included B-1 field homogeneity, optimal Q, spectral bandwidth, resonator ring-down, and sensitivity. Typically, a resonator with 25-mm diameter and 25-mm length was constructed by coupling 11 single loops in parallel with a separation of 2.5 mm. To minimize the resonator ring-down time and provide the necessary spectral bandwidth for in vivo imaging experiments, the Q was reduced predominantly by overcoupling. Capacitative coupling was utilized to minimize microphonic effects. The B-1 field in the resonator was mapped both radially and axially and found to be uniform and adequate for imaging studies. Imaging studies with phantom objects containing a narrow-line spin probe as well as in vivo objects administered with the spin probe show the suitability of these resonators for valid reproduction of the spin probe distribution in three dimensions. The fabrication of such resonators is simple and can be scaled up with relative ease to accommodate larger objects as well. (C) 2000 Academic Press.
引用
收藏
页码:168 / 176
页数:9
相关论文
共 33 条
[1]   A radiofrequency (220-MHz) Fourier transform EPR spectrometer [J].
Alecci, M ;
Brivati, JA ;
Placidi, G ;
Sotgiu, A .
JOURNAL OF MAGNETIC RESONANCE, 1998, 130 (02) :272-280
[2]   ELECTRON-PARAMAGNETIC RESONANCE SPECTROMETER FOR 3-DIMENSIONAL INVIVO IMAGING AT VERY LOW-FREQUENCY [J].
ALECCI, M ;
DELLAPENNA, S ;
SOTGUI, A ;
TESTA, L ;
VANNUCCI, I .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) :4263-4270
[3]   A submicrosecond resonator and receiver system for pulsed magnetic resonance with large samples [J].
Alecci, M ;
Brivati, JA ;
Placidi, G ;
Testa, L ;
Lurie, DJ ;
Sotgiu, A .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :162-166
[4]   EPR and DNP properties of certain novel single electron contrast agents intended for oximetric imaging [J].
Ardenkjær-Larsen, JH ;
Laursen, I ;
Leunbach, I ;
Ehnholm, G ;
Wistrand, LG ;
Petersson, JS ;
Golman, K .
JOURNAL OF MAGNETIC RESONANCE, 1998, 133 (01) :1-12
[5]   MAGNETIC-RESONANCE IMAGING OF BIOLOGICAL SPECIMENS BY ELECTRON-PARAMAGNETIC RESONANCE OF NITROXIDE SPIN LABELS [J].
BERLINER, LJ ;
FUJII, H .
SCIENCE, 1985, 227 (4686) :517-519
[6]   RADIOFREQUENCY FT EPR SPECTROSCOPY AND IMAGING [J].
BOURG, J ;
KRISHNA, MC ;
MITCHELL, JB ;
TSCHUDIN, RG ;
POHIDA, TJ ;
FRIAUF, WS ;
SMITH, PD ;
METCALFE, J ;
HARRINGTON, F ;
SUBRAMANIAN, S .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 102 (01) :112-115
[7]   OVERCOUPLING NMR PROBES TO IMPROVE TRANSIENT-RESPONSE [J].
CHINGAS, GC .
JOURNAL OF MAGNETIC RESONANCE, 1983, 54 (01) :153-157
[8]   Three-dimensional pulsed ESR imaging [J].
Coy, A ;
Kaplan, N ;
Callaghan, PT .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 121 (02) :201-205
[9]   THE LOOP-GAP RESONATOR - A NEW MICROWAVE LUMPED CIRCUIT ELECTRON-SPIN-RESONANCE SAMPLE STRUCTURE [J].
FRONCISZ, W ;
HYDE, JS .
JOURNAL OF MAGNETIC RESONANCE, 1982, 47 (03) :515-521
[10]   DOUBLY WOUND COILS FOR SOLID-STATE DOUBLE-RESONANCE AND MULTIPLE-PULSE NMR [J].
FRY, CG ;
IWAMIYA, JH ;
APPLE, TM ;
GERSTEIN, BC .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (01) :214-216