On-chip absorption measurements using an integrated waveguide

被引:31
作者
Splawn, BG [1 ]
Lytle, FE [1 ]
机构
[1] Purdue Univ, Dept Chem, Brown Labs 1393, W Lafayette, IN 47907 USA
关键词
waveguides; absorption detection; capillary electrophoresis; poly-dimethylsiloxane; chip;
D O I
10.1007/s00216-002-1316-9
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Square hollow waveguides are used to integrate measurement of absorption with chip-based electrophoresis. The 50x50 mum liquid channel and 50x50 mum waveguide are etched as a negative pattern into a silicon master and replicated as a positive in poly-dimethylsiloxane (PDMS). The uniform refractive index of the chip prevents guiding by total internal reflection. Instead, light at 488 nm is guided by reflection at the air-PDMS interface. The waveguide has a 60% efficiency over a distance of 3.2 cm. Separation of fluorescein and the dye BODIPY is demonstrated. A detection limit (S/N=3) of 200 muM fluorescein is obtained using a 50 mum pathlength and a simple photocell detector.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 19 条
[1]
LOSS CALCULATIONS FOR ANTIRESONANT WAVE-GUIDES [J].
ARCHAMBAULT, JL ;
BLACK, RJ ;
LACROIX, S ;
BURES, J .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1993, 11 (03) :416-423
[2]
Born M., 1986, PRINCIPLES OPTICS
[3]
Burke BJ, 2001, ELECTROPHORESIS, V22, P3744, DOI 10.1002/1522-2683(200109)22:17<3744::AID-ELPS3744>3.0.CO
[4]
2-7
[5]
An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[6]
Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[7]
Computer simulations of electrokinetic injection techniques in microfluidic devices [J].
Ermakov, SV ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3512-3517
[8]
Hollow plastic waveguides for sensor applications [J].
George, RJ ;
Harrington, JA .
FIBER OPTIC SENSOR TECHNOLOGY II, 2001, 4204 :230-237
[9]
Minimizing the number of voltage sources and fluid reservoirs for electrokinetic valving in microfluidic devices [J].
Jacobson, SC ;
Ermakov, SV ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3273-3276
[10]
PRECOLUMN REACTIONS WITH ELECTROPHORETIC ANALYSIS INTEGRATED ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4127-4132