Solid-Contact Reference Electrodes Based on Lipophilic Salts

被引:65
作者
Mattinen, Ulriika [1 ,2 ]
Bobacka, Johan [1 ,2 ]
Lewenstam, Andrzej [1 ,2 ,3 ]
机构
[1] Abo Akad Univ, Ctr Proc Analyt Chem & Sensor Technol ProSens, FI-20500 Turku, Finland
[2] Abo Akad Univ, Analyt Chem Lab, Proc Chem Ctr, FI-20500 Turku, Finland
[3] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
Solid-contact reference electrode; Galvanic cell; Potentiometry; Potential formation mechanism; PVC membrane; Membranes; Lipophilicity; STATE REFERENCE ELECTRODES; LIQUID-JUNCTION; MEMBRANE;
D O I
10.1002/elan.200904615
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel solid-contact reference electrode (SCRE) for potentiometric measurements is studied. A lipophilic salt was introduced into a PVC membrane by two different approaches, i) using tetra(alkyl)ammonium-tetra(butyl or phenyl) borate, i.e. a single salt (Phi(+)Psi(-)) and ii) tetra (alkyl)ammonium chloride + potassium tetra(phenyl)borate i.e. two salts (Phi Cl-+(-)) and (K+Psi(-)) that presumably form (T(alkyl)A(+)T(phenyl)B-) and potassium chloride (KCl) in the membrane. The effect of the salt size on the performance of the SCRE was studied by preparing membranes using compounds with varying alkyl chain lengths. To get reference electrodes, these membranes were drop cast on two different substrates: glassy carbon (GC) disks covered with the conductive polymer (poly(3,4-ethylenedioxythiophene) doped with chloride (PEDOT-Cl), or silver disks coated with silver chloride (Ag/AgCl). The potential response of these electrodes was investigated in several potentiometric experiments using a conventional double junction silver chloride electrode as a reference. It was found that electrodes with the tetrabutylammonium tetrabutylborate (TBA-TBB, single salt) in the membrane were insensitive to changes in electrolyte concentrations but reached stable potentials slowly after changes in the sample electrolyte. The double salt approach, where KCl was also present in the membrane, improved the response time, but these electrodes were more sensitive to concentration changes.
引用
收藏
页码:1955 / 1960
页数:6
相关论文
共 26 条
[1]  
Bakker E, 1999, ELECTROANAL, V11, P788, DOI 10.1002/(SICI)1521-4109(199907)11:10/11<788::AID-ELAN788>3.0.CO
[2]  
2-4
[3]   Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix [J].
Blaz, T ;
Migdalski, J ;
Lewenstam, A .
ANALYST, 2005, 130 (05) :637-643
[4]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[5]   Use of ion-selective electrodes for blood-electrolyte analysis.: Recommendations for nomenclature, definitions and conventions [J].
Burnett, RW ;
Covington, AK ;
Fogh-Andersen, N ;
Külpmann, WR ;
Lewenstam, A ;
Maas, AHJ ;
Müller-Plathe, O ;
VanKessel, AL ;
Zijlstra, WG .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (04) :363-370
[6]   EVALUATION OF A NEW SOLID-STATE REFERENCE ELECTRODE JUNCTION MATERIAL FOR ION-SELECTIVE ELECTRODES [J].
DIAMOND, D ;
MCENROE, E ;
MCCARRICK, M ;
LEWENSTAM, A .
ELECTROANALYSIS, 1994, 6 (11-12) :962-971
[7]   Towards a solid state reference electrode [J].
Eine, K ;
Kjelstrup, S ;
Nagy, K ;
Syverud, K .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) :381-388
[8]   Metal/polypyrrole quasi-reference electrode for voltammetry in nonaqueous and aqueous solutions [J].
Ghilane, Jalal ;
Hapiot, Philippe ;
Bard, Allen J. .
ANALYTICAL CHEMISTRY, 2006, 78 (19) :6868-6872
[9]   Solid-state reference electrodes for potentiometric sensors [J].
Guth, U. ;
Gerlach, F. ;
Decker, M. ;
Oelssner, W. ;
Vonau, W. .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (01) :27-39
[10]   A polymeric junction membrane for solid-state reference electrodes [J].
Ha, J ;
Martin, SM ;
Jeon, Y ;
Yoon, IJ ;
Brown, RB ;
Nam, H ;
Cha, GS .
ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) :59-66