A redox-label immunosensor on basis of a bi-enzyme electrode

被引:16
作者
Bier, FF
EhrentreichForster, E
Dolling, R
Eremenko, AV
Scheller, FW
机构
[1] BIOTEZ BERLIN BUCH GMBH,D-13122 BERLIN,GERMANY
[2] RES CTR MOL DIAGNOST & THERAPY,MOSCOW 113149,RUSSIA
关键词
biosensors; immunosensor; redox-label; bi-enzyme amplifier;
D O I
10.1016/S0003-2670(97)00050-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzymatic analyte recycling results in detection limits at the nanomolar level thus allowing for the coupling to immunoassay detection. For this reason a bifunctional reagent was synthesized, which has the two properties of being a redox active substance, for a bi-enzymatic redox-cycling system on one hand, and as being a competitor, e.g. a label, for the analyte in an immunoassay on the other hand. Such compounds, called redox-labels, enable the construction of a real immunosensor, which works without any addition of substrates, The principle is demonstrated with the determination of 2,4-dichlorophenoxyacetic acid (2,4-D).
引用
收藏
页码:119 / 124
页数:6
相关论文
共 26 条
[1]   ENZYME IMMUNOSENSOR .2. ELECTROCHEMICAL DETERMINATION OF IGG WITH AN ANTIBODY-BOUND MEMBRANE [J].
AIZAWA, M ;
MORIOKA, A ;
SUZUKI, S .
JOURNAL OF MEMBRANE SCIENCE, 1978, 4 (02) :221-228
[2]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[3]   An enzymatic amplification cycle for high sensitive immunoassay [J].
Bier, FF ;
EhrentreichForster, E ;
Makower, A ;
Scheller, FW .
ANALYTICA CHIMICA ACTA, 1996, 328 (01) :27-32
[4]  
Bier FF, 1996, FRESEN J ANAL CHEM, V354, P861
[5]   Ultrasensitive biosensors [J].
Bier, FF ;
EhrentreichForster, E ;
Scheller, FW ;
Makower, A ;
Eremenko, A ;
Wollenberger, U ;
Bauer, CG ;
Pfeiffer, D ;
Michael, N .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :5-12
[6]   A bienzyme electrode for tyrosine-containing peptides determination [J].
Eremenko, AV ;
Makower, A ;
Bauer, CG ;
Kurochkin, IN ;
Scheller, FW .
ELECTROANALYSIS, 1997, 9 (04) :288-292
[7]   MONOCLONAL ELISA FOR 2,4-DICHLOROPHENOXYACETIC ACID - CHARACTERIZATION OF ANTIBODIES AND ASSAY OPTIMIZATION [J].
FRANEK, M ;
KOLAR, V ;
GRANATOVA, M ;
NEVORANKOVA, Z .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (06) :1369-1374
[8]   DETERMINATION OF P-AMINOPHENOL AND CATECHOLAMINES AT PICOMOLAR CONCENTRATIONS BASED ON RECYCLING ENZYME AMPLIFICATION [J].
GHINDILIS, AL ;
MAKOWER, A ;
BAUER, CG ;
BIER, FF ;
SCHELLER, FW .
ANALYTICA CHIMICA ACTA, 1995, 304 (01) :25-31
[9]  
GHINDILIS AL, 1995, ANAL METHOD INSTRUM, V2, P129
[10]  
GHINDILIS AL, 1995, ANAL LETT, V28, P1