Small animal absorbed radiation dose from serial micro-computed tomography imaging

被引:75
作者
Carlson, Stephanie K.
Classic, Kelly L.
Bender, Claire E.
Russell, Stephen J.
机构
[1] Mayo Clin & Mayo Fdn, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Sect Safety, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Program Mol Med, Rochester, MN 55905 USA
关键词
small animal imaging; molecular imaging; micro-CT; radiation dose;
D O I
10.1007/s11307-007-0080-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To determine the radiation dose to mouse cancer xenografts from serial micro-computed tomography (CT) examinations. Procedures: A nude mouse with a 15-mm subcutaneous pancreatic cancer xenograft in the rightflank was used. Radiation exposure to the subcutaneous tumor and the mouse pancreas (to simulate an orthotopic pancreatic tumor model) was measured using lithium fluoride thermoluminescent dosimeters. Ultrafast micro-CT was performed using 80 kVp, 0.26 mA, 0.156 mm slice thickness, 256 slices, 0.7 mm Al filtration, and 60-second image acquisition time (15 mA second). Micro-CT imaging acquisitions were repeated four times. Results: We measured consistently low tumor doses (0.014 to 0.02 Gy; average = 0.017 Gy) per scan. Orthotopic doses in the region of the pancreas were also consistently low (0.014 to 0.018 Gy; average = 0.016 Gy) per scan. Conclusions: Radiation doses delivered during ultrafast micro-CT serial imaging in the mouse are low and are likely below the threshold to affect tumor growth.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 21 条
[1]
Adams A., 2006, MOL IMAGING BIOL, V8, P76
[2]
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
[3]
In vivo quantitation of intratumoral radioisotope uptake using micro-single photon emission computed tomography/computed tomography [J].
Carlson, Stephanie K. ;
Classic, Kelly L. ;
Hadac, Elizabeth M. ;
Bender, Claire E. ;
Kemp, Bradley J. ;
Lowe, Val J. ;
Hoskin, Tanya L. ;
Russell, Stephen J. .
MOLECULAR IMAGING AND BIOLOGY, 2006, 8 (06) :324-332
[4]
Cavanaugh Dawn, 2004, Mol Imaging, V3, P55, DOI 10.1162/153535004773861723
[5]
DAIBES S, 2004, MOL IMAGING, V3, P245
[6]
Epperly MW, 2006, IN VIVO, V20, P333
[7]
Fundamental image quality limits for microcomputed tomography in small animals [J].
Ford, NL ;
Thornton, MM ;
Holdsworth, DW .
MEDICAL PHYSICS, 2003, 30 (11) :2869-2877
[8]
Radiation dose estimate in small animal SPECT and PET [J].
Funk, T ;
Sun, MS ;
Hasegawa, BH .
MEDICAL PHYSICS, 2004, 31 (09) :2680-2686
[9]
Simultaneous molecular and anatomical imaging of the mouse in vivo [J].
Goertzen, AL ;
Meadors, AK ;
Silverman, RW ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (24) :4315-4328
[10]
GOERTZEN AL, 2003, THESIS U CALIFORNIA