In vivo quantitation of intratumoral radioisotope uptake using micro-single photon emission computed tomography/computed tomography

被引:46
作者
Carlson, Stephanie K.
Classic, Kelly L.
Hadac, Elizabeth M.
Bender, Claire E.
Kemp, Bradley J.
Lowe, Val J.
Hoskin, Tanya L.
Russell, Stephen J.
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Sect Safety, Rochester, MN 55905 USA
[3] Mayo Clin, Program Mol Med, Rochester, MN 55905 USA
[4] Mayo Clin, Div Biostat, Rochester, MN 55905 USA
关键词
molecular imaging; quantitation; SPECT; micro-SPECT; mice; sodium iodide symporter (NIS) gene; measles virus; reporter gene;
D O I
10.1007/s11307-006-0058-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study was undertaken to determine the ability of micro-single photon emission computed tomography (micro-SPECT)/computed tomography (CT) to accurately quantitate intratumoral radioisotope uptake in vivo and to compare these measurements with planar imaging and micro-SPECT imaging alone. Procedures: Human pancreatic cancer xenografts were established in 10 mice. Intratumoral radioisotope uptake was achieved via intratumoral injection of an attenuated measles virus vector expressing the NIS gene (MV-NIS). On various days after MV-NIS injection, 123 1 planar and micro-SPECT/CT imaging was performed. Tumor activity was determined by dose calibrator measurements and region-of-interest (ROI) image analysis. Agreement and reproducibility of tumor activity measurements were assessed by Bland-Altman plots and Lin's concordance correlation coefficient (CCC). Results: Intratumoral radioisotope uptake was detected in all mice. Scatterplots demonstrate strong agreement (CCC=0.93) between micro-SPECT/CT ROI image analysis and dose calibrator tumor activity measurements. The differences between dose calibrator activity measurements and those obtained with ROI image analysis of micro-SPECT alone and planar imaging are less accurate and more variable (CCC=0.84 and 0.78, respectively). Conclusions: Micro-SPECT/CT can be used to accurately quantify intratumoral radioisotope uptake in vivo and is more reliable than planar or micro-SPECT imaging alone.
引用
收藏
页码:324 / 332
页数:9
相关论文
共 32 条
[1]  
Beekman FJ, 2005, J NUCL MED, V46, P1194
[2]   Correlation of red marrow radiation dosimetry with myelotoxicity:: Empirical factors influencing the radiation-induced myelotoxicity of radiolabeled antibodies, fragments and clinical settings [J].
Behr, TM ;
Béhé, M ;
Sgouros, G .
CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2002, 17 (04) :445-464
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Quantification of iodine-131 in tumors using a threshold based on image contrast [J].
DeNardo, GL ;
Shen, S ;
DeNardo, SJ ;
Liao, SQ ;
Lamborn, KR ;
DeNardo, DA ;
Yuan, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (05) :497-502
[5]  
Dewaraja YK, 2005, J NUCL MED, V46, P840
[6]   In vivo imaging and tumor therapy with the sodium iodide symporter [J].
Dingli, D ;
Russell, SJ ;
Morris, JC .
JOURNAL OF CELLULAR BIOCHEMISTRY, 2003, 90 (06) :1079-1086
[7]   The specific uptake size index for quantifying radiopharmaceutical uptake [J].
Fleming, JS ;
Bolt, L ;
Stratford, JS ;
Kemp, PM .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14) :N227-N234
[8]   Dual-Modality Imaging of Cancer with SPECT/CT [J].
Hasegawa, Bruce H. ;
Wong, Kenneth H. ;
Iwata, Koji ;
Barber, William C. ;
Hwang, Andrew B. ;
Sakdinawat, Anne E. ;
Ramaswamy, Mohan ;
Price, David C. ;
Hawkins, Randall A. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2002, 1 (06) :449-458
[9]   Attenuation correction for small animal SPECT imaging using x-ray CT data [J].
Hwang, AB ;
Hasegawa, BH .
MEDICAL PHYSICS, 2005, 32 (09) :2799-2804
[10]  
IMAM S, 2001, CANCER BIOTHER RADI, V16, P244