Initial clinical experience with contrast-enhanced digital breast tomosynthesis

被引:88
作者
Chen, Sara C.
Carton, Ann-Katherine
Albert, Michael
Conant, Emily F.
Schnall, Mitchell D.
Maidment, Andrew D. A.
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Philadelphia, PA 19104 USA
关键词
breast imaging; technical development; contrast-enhanced digital mammography; contrast-enhanced digital breast tomosynthesis; breast MR;
D O I
10.1016/j.acra.2006.10.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Contrast-enhanced digital mammography and digital breast tomosynthesis are two imaging techniques that attempt to increase malignant breast lesion conspicuity. The combination of these into a single technique, contrast-enhanced digital breast tomosynthesis (CE-DBT), could potentially integrate the strengths of both. The objectives of this study were to assess the clinical feasibility of CE-DBT as an adjunct to digital mammography, and to correlate lesion enhancement characteristics and morphology obtained with CE-DBT to digital mammography, ultrasound, and magnetic resonance (MR). Materials and Methods. CE-DBT (GE Senographe 20001); Milwaukee, WI) was performed as a pilot study in an ongoing National Cancer Institute-funded grant (P01-CA85484) studying multimodality breast imaging. Thirteen patients with ACR BI-RADS category 4 or 5 breast lesions underwent imaging with digital mammography, ultrasound, MR, and CE-DBT. CE-DBT was performed at 49 kVp with a rhodium target and a 0.27-mm copper (Alfa Aesar, Ward Hill, MA) filter. Preinjection and postinjection DBT image sets were acquired in the medial lateral oblique projection with slight compression. Each image set consists of nine images acquired over a 50-degree arc and was obtained with a mean glandular x-ray dose comparable to two conventional mammographic views. Between the precontrast and postcontrast DBT image sets, a single bolus of iodinated contrast agent (1 ml/kg at 2 ml/s, Omnipaque-300; Amersham Health Inc., Princeton, NJ) was administered. Images were reconstructed using filtered-backprojection in 1-mm increments and transmitted to a clinical PACS workstation. Results. Initial experience suggests that CE-DBT provides morphologic and vascular characteristics of breast lesions qualitatively concordant with that of digital mammography and MR. Conclusion. As an adjunct to digital mammography, CE-DBT may be a potential alternative tool for breast lesion morphologic and vascular characterization.
引用
收藏
页码:229 / 238
页数:10
相关论文
共 29 条
[1]   BREAST-LESIONS EXAMINED BY DIGITAL ANGIOGRAPHY - WORK IN PROGRESS [J].
ACKERMAN, LV ;
WATT, AC ;
SHETTY, P ;
FLYNN, MJ ;
BURKE, M ;
KAMBOURIS, A ;
FINE, G ;
WILDERMAN, S .
RADIOLOGY, 1985, 155 (01) :65-68
[2]  
American College of Radiology (ACR), 2003, ACR Breast Imaging Reporting and Data System: Breast Imaging Atlas, V4th ed.
[3]   MR CHARACTERIZATION OF SUSPICIOUS BREAST-LESIONS WITH A GADOLINIUM-ENHANCED TURBOFLASH SUBTRACTION TECHNIQUE [J].
BOETES, C ;
BARENTSZ, JO ;
MUS, RD ;
VANDERSLUIS, RF ;
VANERNING, LJTO ;
HENDRIKS, JHCL ;
HOLLAND, R ;
RUYS, SHJ .
RADIOLOGY, 1994, 193 (03) :777-781
[4]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[5]   Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data [J].
Boone, JM .
MEDICAL PHYSICS, 2002, 29 (05) :869-875
[6]   Effect of temporal resolution on the diagnostic efficacy of contrast-enhanced MRI in the conservatively treated breast [J].
Buckley, DL ;
Mussurakis, S ;
Horsman, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (01) :47-51
[7]  
CARTON AK, 2006, MED IMAGING 2006 PHY, P111
[8]   COMPUTED TOMOGRAPHIC MAMMOGRAPHY USING A CONVENTIONAL BODY SCANNER [J].
CHANG, CHJ ;
NESBIT, DE ;
FISHER, DR ;
FRITZ, SL ;
DWYER, SJ ;
TEMPLETON, AW ;
LIN, F ;
JEWELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (03) :553-558
[9]   Digital mammography using iodine-based contrast media [J].
Diekmann, F ;
Diekmann, S ;
Jeunehomme, F ;
Muller, S ;
Hamm, B ;
Bick, U .
INVESTIGATIVE RADIOLOGY, 2005, 40 (07) :397-404
[10]   DIFFERENTIATION OF BENIGN FROM MALIGNANT BREAST MASSES BY TIME-INTENSITY EVALUATION OF CONTRAST-ENHANCED MRI [J].
FLICKINGER, FW ;
ALLISON, JD ;
SHERRY, RM ;
WRIGHT, JC .
MAGNETIC RESONANCE IMAGING, 1993, 11 (05) :617-620