Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data

被引:185
作者
Boone, JM [1 ]
机构
[1] Univ Calif Davis, Dept Radiol, Sacramento, CA 95817 USA
关键词
glandular breast dose; mammography; Monte Carlo; computers; DgN;
D O I
10.1118/1.1472499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Normalized glandular dose (DgN) values have been reported by several investigators for specific spectra, however for unconventional or unanticipated x-ray spectra considered for use in mammography, practical methods are not available for DgN computation, In this study, the previously validated SIERRA Monte Carlo code was used to compute the normalized glandular dose coefficients for monoenergetic energies from 8 keV to 50 keV. The overall mammography geometry used was a 65 cm source to image distance, a 1.2 cm air gap between the breast and the detector, and breast thicknesses ranging from 2 to 9 cm. A 4 mm layer of skin was also modeled, and semicircular breast radii of 8.5 cm and 10.0 cm were studied. Breast compositions of 0% glandular, 50% glandular, and 100% glandular were evaluated. The Monte Carlo derived DgN results demonstrated coefficients of variation less than 0.3%. The monoenergetic DgN values, DgN(E), were computer fit using commercial software and the best fit equations are reported. All fits resulted in r(2) values of 0.9999 or better. The computer fit equations, along with easy to use spectral modeling routines, are available electronically on the web. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:869 / 875
页数:7
相关论文
共 25 条
[1]   DUAL-ENERGY SUBTRACTION MAMMOGRAPHY [J].
ASAGA, T ;
MASUZAWA, C ;
YOSHIDA, A ;
MATSUURA, H .
JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) :70-73
[2]   Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment [J].
Boone, JM .
RADIOLOGY, 1999, 213 (01) :23-37
[3]   Scatter/primary in mammography: Comprehensive results [J].
Boone, JM ;
Lindfors, KK ;
Cooper, VN ;
Seibert, JA .
MEDICAL PHYSICS, 2000, 27 (10) :2408-2416
[4]   Monte Carlo validation in diagnostic radiological imaging [J].
Boone, JM ;
Buonocore, MH ;
Cooper, VN .
MEDICAL PHYSICS, 2000, 27 (06) :1294-1304
[5]   Scatter/primary in mammography: Monte Carlo validation [J].
Boone, JM ;
Cooper, VN .
MEDICAL PHYSICS, 2000, 27 (08) :1818-1831
[6]   DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS [J].
BOONE, JM ;
SHABER, GS ;
TECOTZKY, M .
MEDICAL PHYSICS, 1990, 17 (04) :665-675
[7]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[8]   Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[9]   Comparison of x-ray cross sections for diagnostic and therapeutic medical physics [J].
Boone, JM ;
Chavez, AE .
MEDICAL PHYSICS, 1996, 23 (12) :1997-2005
[10]   MAMMOGRAPHY WITH SYNCHROTRON-RADIATION [J].
BURATTINI, E ;
COSSU, E ;
DIMAGGIO, C ;
GAMBACCINI, M ;
INDOVINA, PL ;
MARZIANI, M ;
POCEK, M ;
SIMEONI, S ;
SIMONETTI, G .
RADIOLOGY, 1995, 195 (01) :239-244