Development of generic continuous-flow enzyme immunoassay system for analysis of aminoglycosides in serum

被引:12
作者
Darwish, IA [1 ]
机构
[1] Assiut Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Assiut 71516, Egypt
关键词
aminoglycoside antibiotics; tobramycin; enzyme immunoassay; continuous flow; serum;
D O I
10.1016/S0731-7085(02)00543-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple generic continuous-flow enzyme immunoassay (CFEIA) for analysis of aminoglycosides in serum has been successfully developed. The developed assay employed a specific monoclonal antibody and beta-galactosidase (beta-GAL) enzyme as label. The assay involves an off-line competitive binding reaction between the analyte and free labelled analyte for the binding sites of the antibody. After equilibrium is reached, the sample was injected into the flow system. The bound antibody complexes with the analyte and the labelled analyte were trapped in a protein G column, while the unbound free labelled analyte was eluted and detected colorimetrically down-stream, after reaction with chlorophenolic red-beta-D-galactopyranoside as a substrate for the beta-GAL enzyme. The concentration of the analyte in a sample was quantified by its ability to inhibit the binding of the analyte-enzyme conjugate to the antibody, and the signal was directly proportional to the concentration of the analyte in the original sample. The optimum conditions for the developed CFEIA were investigated and applied to the analysis of tobramycin, as a representative example of the aminoglycosides, in serum samples. The detection limit of the assay was 0.06 mug ml(-1). The assay showed good precision; the coefficients of variation were 2.49-4.33 and 3.30-6.82% for intra- and inter-assay precision, respectively. Serum matrix constituents and the endogenous compounds did not interfere with the assay. Analytical recovery of spiked tobramycin, in the concentration range between 0.5 and 8.0 mug ml(-1), was 101.55 +/- 3.14. The assay results correlated well with those obtained by high-performance liquid chromatography (r = 0.991). All the obtained results strongly demonstrate that the developed CFEIA is a suitable method for a rapid and reliable analysis of aminoglycosides in serum. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:1539 / 1548
页数:10
相关论文
共 34 条
[1]  
Ackerman BH, 1996, PHARMACOTHERAPY, V16, P201
[2]   Eradication of mucoid Pseudomonas aeruginosa with fluid liposome-encapsulated tobramycin in an animal model of chronic pulmonary infection [J].
Beaulac, C ;
ClementMajor, S ;
Hawari, J ;
Lagace, J .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1996, 40 (03) :665-669
[3]   Antibody-based sensors for heavy metal ions [J].
Blake, DA ;
Jones, RM ;
Blake, RC ;
Pavlov, AR ;
Darwish, IA ;
Yu, HN .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :799-809
[4]   UV-TREATED POLYSTYRENE MICROTITRE PLATES FOR USE IN AN ELISA TO MEASURE ANTIBODIES AGAINST SYNTHETIC PEPTIDES [J].
BOUDET, F ;
THEZE, J ;
ZOUALI, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 142 (01) :73-82
[5]   An enzyme flow immunoassay that uses β-galactosidase as the label and a cellobiose dehydrogenase biosensor as the label detector [J].
Burestedt, E ;
Nistor, C ;
Schagerlöf, U ;
Emnéus, J .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4171-4177
[6]   Competitive immunoassay method for 5-methyl-2′-deoxycytidine [J].
Darwish, I ;
Emara, S ;
Askal, H ;
El-Rabbat, N ;
Omura, K ;
Hirose, K ;
Akizawa, T ;
Yoshioka, M .
ANALYTICA CHIMICA ACTA, 2000, 413 (1-2) :79-86
[7]   Preparation of a specific monoclonal antibody against 2′-deoxycytidine [J].
Darwish, I ;
Akizawa, T ;
Hirose, K ;
Omura, K ;
El-Rabbat, N ;
Yoshioka, M .
ANALYTICA CHIMICA ACTA, 1998, 365 (1-3) :121-128
[8]   Enzyme-linked immunosorbent assay for 2-deoxycytidine [J].
Darwish, I ;
Emara, S ;
Askal, H ;
El-Rabbat, N ;
Akizawa, T ;
Yoshiokab, M .
ANALYTICA CHIMICA ACTA, 2000, 404 (02) :179-186
[9]   Development and validation of a one-step immunoassay for determination of cadmium in human serum [J].
Darwish, IA ;
Blake, DA .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :52-58
[10]   One-step competitive immunoassay for cadmium ions: Development and validation for environmental water samples [J].
Darwish, IA ;
Blake, DA .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1889-1895