High precision measurement of germanium isotope ratio variations by multiple collector-inductively coupled plasma mass spectrometry

被引:28
作者
Galy, A
Pomiès, C
Day, JA
Pokrovsky, OS
Schott, J
机构
[1] Univ Cambridge, Dept Earth Sci, Cambridge CB2 3EQ, England
[2] UPS, OMP, CNRS,UMR 5563, LMTG, F-31400 Toulouse, France
关键词
D O I
10.1039/b210233a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multicollector ICP-MS is used for the precise measurement of variations in the isotopic composition of germanium. Argon-based spectral interferences are assessed in the germanium mass region and the repeatability of the following ratios is determined: Ge-74/Ge-70, Ge-73/Ge-70 and Ge-72/Ge-70. The isotope ratio repeatability of a mono-elemental solution relative to another mono-elemental solution is better than 0.06parts per thousand per u at 95% confidence. Variations in sample Ge-74/Ge-70, Ge-73/Ge-70, and Ge-72/Ge-70 ratios are expressed as delta(74)Ge delta(73)Ge and delta(72)Ge units, respectively, which are deviations in parts per 10(3) from the same ratio in the standard solution. The addition of sodium and potassium to a standard solution of germanium having a known isotopic composition induces up to 4.4parts per thousand decrease of delta(74)Ge. This chemical bias is a result of a mass-dependent process and prevents the measurement of natural samples without chemical separation. Germanium is quantitatively separated from alkali matrix using liquid chromatography techniques.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 24 条
[1]   Nonbiological fractionation of iron isotopes [J].
Anbar, AD ;
Roe, JE ;
Barling, J ;
Nealson, KH .
SCIENCE, 2000, 288 (5463) :126-128
[2]   Natural mass-dependent variations in the isotopic composition of molybdenum [J].
Barling, J ;
Arnold, GL ;
Anbar, AD .
EARTH AND PLANETARY SCIENCE LETTERS, 2001, 193 (3-4) :447-457
[3]   A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58
[4]   High precision measurement of iron isotopes by plasma source mass spectrometry [J].
Belshaw, NS ;
Zhu, XK ;
Guo, Y ;
O'Nions, RK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :191-195
[5]  
Criss R. E., 1999, Priniciples of stable isotope distribution, DOI [10.1093/oso/9780195117752.001.0001, DOI 10.1093/OSO/9780195117752.001.0001]
[6]  
DELAETER JR, 1991, PURE APPL CHEM, V63, P991
[7]   Mg isotopic composition of carbonate: insight from speleothem formation [J].
Galy, A ;
Bar-Matthews, M ;
Halicz, L ;
O'Nions, RK .
EARTH AND PLANETARY SCIENCE LETTERS, 2002, 201 (01) :105-115
[8]  
Galy A, 2002, GEOCHIM COSMOCHIM AC, V66, pA259
[9]   High-precision measurement of magnesium isotopes by multiple-collector inductively coupled plasma mass spectrometry [J].
Galy, A ;
Belshaw, NS ;
Halicz, L ;
O'Nions, RK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) :89-98
[10]   The formation of chondrules at high gas pressures in the solar nebula [J].
Galy, A ;
Young, ED ;
Ash, RD ;
O'Nions, RK .
SCIENCE, 2000, 290 (5497) :1751-1753