Comparison of methods of measurements of oxygen consumption in mechanically ventilated patients with multiple trauma: The Fick method versus indirect calorimetry

被引:29
作者
Epstein, CD
Peerless, JR
Martin, JE
Malangoni, MA
机构
[1] Case Western Reserve Univ, Frances Payne Bolton Sch Nursing, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Surg, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Pulm Serv, Cleveland, OH 44106 USA
关键词
oxygen consumption; multiple trauma; Fick method; indirect calorimetry; lung injury; oxygen delivery; multiple organ dysfunction syndrome; oxygen extraction ratio; oxygen transport; surgical intensive care;
D O I
10.1097/00003246-200005000-00017
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The purpose of this study was to compare the measurements of whole body oxygen consumption determined by the Fick method and by indirect calorimetry in mechanically ventilated patients with multiple trauma. Design: A prospective, correlational, within-subjects design. Setting: Surgical intensive care unit of a Level I trauma center. Patients: Thirty-eight mechanically ventilated adults with multiple injuries who received a pulmonary artery catheter within 24 hrs of admission to the surgical intensive care unit. Measurements and Main Results:After the initial resuscitation, simultaneous measurements of oxygen consumption ((V) over dotO(2)) by the reverse Fick equation and by indirect calorimetry were performed every 6 hrs for 24 hrs in normothermic patients who were at rest for at least 30 mins. At each measurement period, the mean (V) over dotO(2) values determined by indirect calorimetry were significantly greater than the mean (V) over dotO(2), values determined by the Fick method (time 1: 172 +/- 38 vs. 125 +/- 47 mL/min/m(2), p < .0001; time 2: 170 +/- 31 vs. 130 +/- 48 mL/min/m(2), p < .0001; time 3: 170 +/- 32 vs. 132 +/- 53 mL/min/m(2), p < .0001; time 4: 169 +/- 29 vs. 130 +/- 60 mL/min/m(2), p < .0002). By using the Bland and Altman technique, the mean bias was 41 +/- 3.95 mL/min/m(2). Correlation coefficients of (V) over dotO(2) values between methods of measurements were statistically significant (r(2) = .32, p = .0001; r(2) = .32, p = .0001; r(2) = .33, p = .0001; r(2) = .18, p = .0001). Conclusions: Indirect calorimetry should be the preferred standard for measurement of oxygen consumption in severely injured patients.
引用
收藏
页码:1363 / 1369
页数:7
相关论文
共 45 条
[1]   MATHEMATIC COUPLING OF DATA - A COMMON SOURCE OF ERROR [J].
ARCHIE, JP .
ANNALS OF SURGERY, 1981, 193 (03) :296-303
[2]   ERRORS IN MEASUREMENT OF OXYGEN-UPTAKE DUE TO ANESTHETIC-GASES [J].
AUKBURG, SJ ;
GEER, RT ;
WOLLMAN, H ;
NEUFELD, GR .
ANESTHESIOLOGY, 1985, 62 (01) :54-59
[3]   INJURY SEVERITY SCORE - METHOD FOR DESCRIBING PATIENTS WITH MULTIPLE INJURIES AND EVALUATING EMERGENCY CARE [J].
BAKER, SP ;
ONEILL, B ;
HADDON, W ;
LONG, WB .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1974, 14 (03) :187-196
[4]   CONTINUOUS MEASUREMENT OF OXYGEN-UPTAKE - EVALUATION OF THE ENGSTROM METABOLIC COMPUTER AND CLINICAL-EXPERIENCES [J].
BEHRENDT, W ;
WEILAND, C ;
KALFF, J ;
GIANI, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1987, 31 (01) :10-14
[5]   PROSPECTIVE, RANDOMIZED TRIAL OF SURVIVOR VALUES OF CARDIAC INDEX, OXYGEN DELIVERY, AND OXYGEN-CONSUMPTION AS RESUSCITATION END-POINTS IN SEVERE TRAUMA [J].
BISHOP, MH ;
SHOEMAKER, WC ;
APPEL, PL ;
MEADE, P ;
ORDOG, GJ ;
WASSERBERGER, J ;
WO, CJ ;
RIMLE, DA ;
KRAM, HB ;
UMALI, R ;
KENNEDY, F ;
SHULESHKO, J ;
STEPHEN, CM ;
SHORI, SK ;
THADEPALLI, HD .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 38 (05) :780-787
[6]   RELATIONSHIP BETWEEN SUPRANORMAL CIRCULATORY VALUES, TIME DELAYS, AND OUTCOME IN SEVERELY TRAUMATIZED PATIENTS [J].
BISHOP, MH ;
SHOEMAKER, WC ;
APPEL, PL ;
WO, CJ ;
ZWICK, C ;
KRAM, HB ;
MEADE, P ;
KENNEDY, F ;
FLEMING, AW .
CRITICAL CARE MEDICINE, 1993, 21 (01) :56-63
[7]   COMPARISON BETWEEN OXYGEN-CONSUMPTION CALCULATED BY FICKS PRINCIPLE USING A CONTINUOUS THERMODILUTION TECHNIQUE AND MEASURED BY INDIRECT CALORIMETRY [J].
BIZOUARN, P ;
BLANLOEIL, Y ;
PINAUD, M .
BRITISH JOURNAL OF ANAESTHESIA, 1995, 75 (06) :719-723
[8]   OXYGEN-CONSUMPTION AFTER CARDIAC-SURGERY - A COMPARISON BETWEEN CALCULATION BY FICKS PRINCIPLE AND MEASUREMENT BY INDIRECT CALORIMETRY [J].
BIZOUARN, P ;
SOULARD, D ;
BLANLOEIL, Y ;
GUILLET, A ;
GOARIN, Y .
INTENSIVE CARE MEDICINE, 1992, 18 (04) :206-209
[9]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[10]  
BLASI A, 1980, PULMONARY CIRCULATIO, P19