ADC measurement of abdominal organs and lesions using parallel imaging technique

被引:248
作者
Yoshikawa, Takeshi
Kawamitsu, Hideaki
Mitchell, Donald G.
Ohno, Yoshiharu
Ku, Yonson
Seo, Yasushi
Fujii, Masahiko
Sugimura, Kazuro
机构
[1] Thomas Jefferson Univ, Dept Radiol, Div Magnet Resonance Imaging, Philadelphia, PA 19107 USA
[2] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Hyogo, Japan
[3] Kobe Univ Hosp, Dept Liver & Transplantat Surg, Kobe, Hyogo, Japan
[4] Kobe Univ, Grad Sch Med, Dept Clin Mol Med, Div Diabet Digest & Kidney Dis, Kobe, Hyogo, Japan
关键词
abdomen; diffusion-weighted MRI; MRI;
D O I
10.2214/AJR.05.0778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to assess the reliability and usefulness of parallel imaging for apparent diffusion coefficient (ADC) measurement of abdominal organs and lesions. MATERIALS AND METHODS. Single-shot spin-echo echo-planar diffusion-weighted MRI (TE = 66, b = 0, 600 s/mm(2)) was performed in phantom and clinical studies. The b value was set to minimize the effects of perfusion in tissue and to maintain signal-to-noise ratio. Bottle phantoms were scanned with and without parallel imaging and with various parallel imaging factors and at various positions to evaluate the effects of parallel imaging on ADCs. In 200 consecutive clinical patients (122 men and 78 women: mean age, 61.9 years), ADCs were calculated for liver (four segments), spleen, pancreas (head, body, tail), gallbladder, renal parenchyma, and back muscle, and then compared to evaluate the reliability of clinical ADC measurements with parallel imaging. ADCs were also calculated for diffuse diseases and focal lesions (94 malignant and 93 benign) of abdominal organs to evaluate the clinical usefulness of ADC. RESULTS. Location-dependent changes in water ADCs were minimal with parallel imaging factors first of 3, then of 4, and were small except for measurements at the image periphery. Acetone ADCs were saturated at 4.00 x 10(-3) mm(2)/s. Degraded image quality prevented ADC measurement of the left hepatic lobe and pancreas in 7-18 patients. There was no significant difference among ADCs of four liver segments (1.50 +/- 0.24 [SD] x 10-3 mm(2)/s - 1.56 +/- 0.31 x 10(-3) mm(2)/s) and between ADCs of the right and left kidneys (2.65 +/- 0.30 x 10(-3) mm(2)/s, 2.59 +/- 0.33 x 10(-3) mm(2)/s). ADC of the pancreas tail (1.65 +/- 0.37 x 10(-3) mm(2)/s) was significantly lower than those of the head (1.81 +/- 0.40 x 10(-3) mm(2)/s) and body (1.81 +/- 0.41 X 10(-3) mm(2)/s) (p < 0.005). Renal ADCs were significantly lower in patients with renal failure (right: 2.15 +/- 0.30 x 10(-3) mm(2)/s; left: 2.11 +/- 0.25 x 10(-3) mm(2)/s) than in those without disease (right: 2.67 +/- 0.29 x 10(-3) mm(2)/s; left: 2.60 +/- 0.32 x 10(-3) mm(2)/s) (P < 0.005). ADC of pancreatic cancer was significantly higher than that of healthy pancreas (P < 0.05). ADC of renal angiomyolipoma was significantly lower than those of renal cell carcinoma and healthy renal parenchyma (p < 0.0005). CONCLUSION. Clinical ADC measurements of abdominal organs and lesions using parallel imaging appear to be reliable and useful, and the effect of parallel imaging on calculated values is considered to be minimal.
引用
收藏
页码:1521 / 1530
页数:10
相关论文
共 41 条
  • [1] Amano Y, 1998, ACTA RADIOL, V39, P440
  • [2] Cirrhosis: Modified caudate-right lobe ratio
    Awaya, H
    Mitchell, DG
    Kamishima, T
    Holland, G
    Ito, K
    Matsumoto, T
    [J]. RADIOLOGY, 2002, 224 (03) : 769 - 774
  • [3] Diffusion tensor imaging using single-shot SENSE-EPI
    Bammer, R
    Auer, M
    Keeling, SL
    Augustin, M
    Stables, LA
    Prokesch, RW
    Stollberger, R
    Moseley, ME
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 128 - 136
  • [4] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [5] BIHAN DL, 1986, RADIOLOGY, V161, P401
  • [6] Diffusion-weighted MR imaging of the liver of hepatitis C patients
    Boulanger, Y
    Amara, M
    Lepanto, L
    Beaudoin, G
    Nguyen, BN
    Allaire, G
    Poliquin, M
    Nicolet, V
    [J]. NMR IN BIOMEDICINE, 2003, 16 (03) : 132 - 136
  • [7] MR diffusion-weighted imaging of kidney: Differentiation between hydronephrosis and pyonephrosis
    Chan, JHM
    Tsui, EYK
    Luk, SH
    Fung, SL
    Cheung, JK
    Chan, MSM
    Yuen, MK
    Mak, SF
    Wong, KPC
    [J]. CLINICAL IMAGING, 2001, 25 (02) : 110 - 113
  • [8] Diffusion-weighted MR imaging of the liver: distinguishing hepatic abscess from cystic or necrotic tumor
    Chan, JHM
    Tsui, EYK
    Luk, SH
    Fung, ASL
    Yuen, MK
    Szeto, ML
    Cheung, YK
    Wong, KPC
    [J]. ABDOMINAL IMAGING, 2001, 26 (02): : 161 - 165
  • [9] Effect of intravenous gadolinium-DTPA on diffusion-weighted magnetic resonance images for evaluation of focal hepatic lesions
    Chiu, FY
    Jao, JC
    Chen, CY
    Liu, GC
    Jaw, TS
    Chiou, YY
    Hsu, FO
    Hsu, JS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (02) : 176 - 180
  • [10] Single breath-hold diffusion-weighted imaging of the abdomen
    Chow, LC
    Bammer, R
    Moseley, ME
    Sommer, FG
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (03) : 377 - 382