Lab-on-a-Cable for electrochemical monitoring of phenolic contaminants

被引:39
作者
Wang, J [1 ]
Lu, JM
Ly, SY
Vuki, M
Tian, BM
Adeniyi, WK
Armendariz, RA
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] Seoul Natl Univ Technol, Dept Fine Chem, Seoul 139743, South Korea
[3] Univ S Pacific, Dept Chem, Suva, Fiji
[4] N Carolina Agr & Technol State Univ, Dept Chem, Greensboro, NC 27412 USA
关键词
D O I
10.1021/ac991054y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The "Lab-on-a-Cable" concept, based on scaling down an electrochemical flow system to a cable platform, is described. The system integrates the analyte collection and the sample handling, with the electrochemical detection of the reaction product in a sealed cylindrical unit, connected to a long shielded cable. An enzymatic assay, involving collection of a phenolic substrate, its mixing with an internally delivered tyrosinase solution, and amperometric detection of the liberated quinone product, is used for illustrating the operation of the flow probe and demonstrating its advantages over remote phenol sensors. The internal buffer solution ensures independence of sample conditions such as pH, ionic strength, or natural conditions, that commonly influences the performance of remote sensors. The "built-in'" flow pulsation of the integrated micropump is exploited for a sensitive hydrodynamic-modulation voltammetric detection of hydrazine and peroxide pollutants.
引用
收藏
页码:2659 / 2663
页数:5
相关论文
共 15 条
[1]   SUBMICROMOLAR CONCENTRATION MEASUREMENTS WITH TUBULAR ELECTRODES [J].
BLAEDEL, WJ ;
BOYER, SL .
ANALYTICAL CHEMISTRY, 1971, 43 (12) :1538-&
[2]   REMOTE DETECTION OF GROUNDWATER CONTAMINANTS USING FAR-ULTRAVIOLET LASER-INDUCED FLUORESCENCE [J].
CHUDYK, WA ;
CARRABBA, MM ;
KENNY, JE .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1237-1242
[3]   A SUBMERSIBLE FLOW-INJECTION ANALYZER FOR THE IN-SITU DETERMINATION OF NITRITE AND NITRATE IN COASTAL WATERS [J].
DANIEL, A ;
BIROT, D ;
BLAIN, S ;
TREGUER, P ;
LEILDE, B ;
MENUT, E .
MARINE CHEMISTRY, 1995, 51 (01) :67-77
[4]   A submersible flow injection-based sensor for the determination of total oxidised nitrogen in coastal waters [J].
David, ARJ ;
McCormack, T ;
Morris, AW ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 1998, 361 (1-2) :63-72
[5]  
JOHNSON K, 1986, ANAL CHIM ACTA, V176, P245
[6]   INVIVO SAMPLING USING LOOP MICRODIALYSIS PROBES COUPLED TO A LIQUID CHROMATOGRAPH [J].
LINHARES, MC ;
KISSINGER, PT .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 578 (02) :157-163
[7]  
MARKOVARGA G, 1995, TRENDS ANAL CHEM, V14, P1995
[8]   INSITU VOLTAMMETRIC MEASUREMENTS IN NATURAL-WATERS - FUTURE-PROSPECTS AND CHALLENGES [J].
TERCIER, ML ;
BUFFLE, J .
ELECTROANALYSIS, 1993, 5 (03) :187-200
[9]   ENZYME-BASED FIBER OPTIC ZINC BIOSENSOR [J].
THOMPSON, RB ;
JONES, ER .
ANALYTICAL CHEMISTRY, 1993, 65 (06) :730-734
[10]   HYDRODYNAMIC MODULATION VOLTAMMETRY [J].
WANG, J .
TALANTA, 1981, 28 (06) :369-376