First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip

被引:64
作者
Chmeissani, M [1 ]
Frojdh, C
Gal, O
Llopart, X
Ludwig, J
Maiorino, M
Manach, E
Mettivier, G
Montesi, MC
Ponchut, C
Russo, P
Tlustos, L
Zwerger, A
机构
[1] Mid Sweden Univ, Mitthogskolan, Sundsvall, Sweden
[2] CEA, LIST, Saclay, France
[3] CERN, Geneva, Switzerland
[4] Univ Freiburg, Inst Phys, Arbeitsgrp Halbleiterdetektoren, Freiburg, Germany
[5] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[6] Univ Naples Federico II, Dipartimento Sci Fis, I-80126 Naples, Italy
[7] Ist Nazl Fis Nucl, Sez Napoli, I-80126 Naples, Italy
关键词
Me; hybrid detectors; Medipix2;
D O I
10.1109/tns.2004.832324
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present preliminary tests of hybrid pixel detectors consisting of the Medipix2 readout chip bump-bonded to a 1-mm-thick CdTe pixel detector. This room temperature imaging system for single photon counting has been developed within the Medipix2 European Collaboration for various imaging applications with X-rays and gamma rays, including dental radiography, mammography, synchrotron radiation, nuclear medicine, and radiation monitoring in nuclear facilities. The Medipix2 + CdTe hybrid detector features 256 x 256 square pixels, a pitch of 55 mum, a sensitive area of 14 x 14 mm(2). We analyzed the quality of the detector and bump-bonding and the response to nuclear radiation of the first CdTe hybrids. The CdTe pixel detectors, with Pt ohmic contacts, showed an ohmic response when negatively biased up to less than 60 V (electrons collection mode). Tests were also performed in holes collection mode, where a nonresistive behavior was observed above + 15 V. We performed a series of imaging tests at low voltage bias with gamma radioactive sources and with an X-ray tube. Under uniform irradiation, we observed for all detectors the presence of numerous, stable structures in the form of small circles of about 200 mum diameter, with the central pixels showing a reduced counting efficiency with respect to the periphery (in electrons counting regime). Also long filament structures have been observed. Further investigations will reveal whether they are due to an intrinsic detector response (e.g., due to Te inclusions) or to the bump-bonding process.
引用
收藏
页码:2379 / 2385
页数:7
相关论文
共 15 条
[1]   An interface board for the control and data acquisition of the Medipix2 chip [J].
Bello, DS ;
van Beuzekom, M ;
Jansweijer, P ;
Verkooijen, H ;
Visschers, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :164-170
[2]   A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting [J].
Campbell, M ;
Heijne, EHM ;
Meddeler, G ;
Pernigotti, E ;
Snoeys, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :751-753
[3]   Preliminary test of Medisoft 4: Control software for the Medipix2 readout chip [J].
Conti, M ;
Maiorino, M ;
Mettivier, G ;
Montesi, MC ;
Russo, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) :869-877
[4]   A counting CdTe pixel detector for hard X-ray and γ-ray imaging [J].
Fischer, P ;
Kouda, M ;
Krüger, H ;
Lindner, M ;
Sato, G ;
Takahashi, T ;
Watanabe, S ;
Wermes, N .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) :2401-2404
[5]   Growth and characterization of CdTe single crystals for radiation detectors [J].
Funaki, M ;
Ozaki, T ;
Satoh, K ;
Ohno, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :120-126
[6]   First test measurements of a 64k pixel readout chip working in single photon counting mode [J].
Llopart, X ;
Campbell, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :157-163
[7]   Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode [J].
Llopart, X ;
Campbell, M ;
Dinapoli, R ;
Segundo, DS ;
Pemigotti, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2279-2283
[8]  
LLOPART X, 2001, C REC IEEE NUCL SCI
[9]   Tritium digital autoradiography with a Medipix2 hybrid silicon pixel detector [J].
Mettivier, G ;
Montesi, MC ;
Russo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (2-3) :554-563
[10]   First images of a digital autoradiography system based on a Medipix2 hybrid silicon pixel detector [J].
Mettivier, G ;
Montesi, MC ;
Russo, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (12) :N173-N181