Contrast echocardiography: Current and future applications

被引:217
作者
Mulvagh, SL [1 ]
DeMaria, AN [1 ]
Feinstein, SB [1 ]
Burns, PN [1 ]
Kaul, S [1 ]
Miller, JG [1 ]
Monaghan, M [1 ]
Porter, TR [1 ]
Shaw, LJ [1 ]
Villanueva, FS [1 ]
机构
[1] Amer Soc Echocardiog, Raleigh, NC 27607 USA
关键词
D O I
10.1067/mje.2000.105462
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent updates in the held of echocardiography have resulted in improvements in image quality, especially in those patients whose ultrasonographic (ultrasound) evaluation was previously suboptimal Intravenous contrast agents are now available in the United States and Europe for the indication of left ventricular opacification and enhanced endocardial border delineation. The use of contrast enables acquisition of ultrasound images of improved quality. The technique is especially useful in obese patients and those with lung disease. Patients in these categories comprise approximately 10% to 20% of routine echocardiographic examinations. Stress echocardiography examinations can be even more challenging, as the image acquisition time factor is critically important for accurate detection of coronary disease. Improvements in image quality with intravenous contrast agents can facilitate image acquisition and enhance delineation of regional wall motion abnormalities at the peak level of exercise. Recent phase III clinical trial data on the use of Optison and several other agents (currently under evaluation) have revealed that for approximately half of patients, image quality substantively improves, which enables the examination to be salvaged and/or increases diagnostic accuracy. For the "difficult-to-image" patient, this added information results in (1) enhanced Laboratory efficiency, (2) a reduction in downstream testing, and (3) possible improvements in patient outcome. In addition, substantial research efforts are underway to use ultrasound contrast agents for assessment of myocardial perfusion. The detection of myocardial perfusion during echocardiographic examinations will permit the simultaneous assessment of global and regional myocardial structure, function, and perfusion-all of the indicators necessary to enable the optimal noninvasive assessment of coronary artery disease. Despite the added benefit in improved efficacy of testing, few data exist regarding the long-term effectiveness of these agents. Currently under evaluation are the clinical and economic outcome implications of intravenous contrast agent use for daily clinical decision making in a variety of patient subsets. Until these data are known, this document offers a preliminary synthesis of available evidence on the value of intravenous contrast agents for use in rest and stress echocardiography. At present, it is the position of this guideline committee that intravenous contrast agents demonstrate substantial value in the difficult-to-image patient with comorbid conditions limiting an ultrasound evaluation of the heart. For such patients, the use of intravenous contrast agents should be encouraged as a means to provide added diagnostic information and to streamline early detection and treatment of underlying cardiac pathophysiology. As with all new technology, this document will require updates and revisions as additional data become available.
引用
收藏
页码:331 / 342
页数:12
相关论文
共 96 条
[1]  
Agati L, 1997, EUR HEART J, V18, P771
[2]   Usefulness of harmonic imaging for left ventricular opacification and endocardial border delineation by Optison [J].
Al-Mansour, HA ;
Mulvagh, SL ;
Pumper, GM ;
Klarich, KW ;
Foley, DA .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (06) :795-+
[3]   Harmonic imaging: echocardiographic enhanced contrast intensity and duration [J].
Allen, MR ;
Pellikka, PA ;
Villarraga, HR ;
Klarich, KW ;
Foley, DA ;
Mulvagh, SL ;
Seward, JB .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (03) :215-220
[4]  
ALMANSOUR HA, 1998, J AM SOC ECHOCARDIOG, V11, P527
[5]  
BECHER H, IN PRESS HDB CONTRAS
[6]   Prolonged myocardial contrast echocardiography via peripheral venous administration of QW3600 injection (EchoGen(R)): Its efficacy and side effects [J].
Beppu, S ;
Matsuda, H ;
Shishido, T ;
Matsumura, M ;
Kiyatake, K .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (01) :11-24
[7]   Noninvasive in vivo clot dissolution without a thrombolytic drug - Recanalization of thrombosed iliofemoral arteries by transcutaneous ultrasound combined with intravenous infusion of microbubbles [J].
Birnbaum, Y ;
Luo, H ;
Nagai, T ;
Fishbein, MC ;
Peterson, TM ;
Li, SP ;
Kricsfeld, D ;
Porter, TR ;
Siegel, RJ .
CIRCULATION, 1998, 97 (02) :130-134
[8]   Myocardial contrast echocardiography versus dobutamine echocardiography for predicting functional recovery after acute myocardial infarction treated with primary coronary angioplasty [J].
Bolognese, L ;
Antoniucci, D ;
Rovai, D ;
Buonamici, P ;
Cerisano, G ;
Santoro, GM ;
Marini, C ;
LAbbate, A ;
Fazzini, PF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (07) :1677-1683
[9]  
Bootsman M., 1999, Journal of the American College of Cardiology, V33, p408A
[10]  
Burns PN, 1996, CLIN RADIOL, V51, P50