Objective Guidelines for Removing an External Fixator after Tibial Lengthening Using Pixel Value Ratio: A Pilot Study

被引:44
作者
Zhao, Li [3 ]
Fan, Qing [3 ]
Venkatesh, K. P. [1 ,2 ]
Park, Man S. [4 ]
Song, Hae Ryong [1 ,2 ]
机构
[1] Korea Univ, Inst Rare Dis, Coll Med, Guro Hosp, Seoul 152703, South Korea
[2] Korea Univ, Dept Orthoped Surg, Coll Med, Guro Hosp, Seoul 152703, South Korea
[3] Shanghai Jiao Tong Univ, Dept Pediat Orthopaed, Xin Hua Hosp, Sch Med, Shanghai 200030, Peoples R China
[4] Korea Univ, Dept Biostat, Coll Med, Guro Hosp, Seoul 152703, South Korea
关键词
X-RAY ABSORPTIOMETRY; INTRAMEDULLARY NAIL; DISTRACTION OSTEOGENESIS; BONE-FORMATION; CALLUS DISTRACTION; COMPLICATIONS; CALLOTASIS; MINERALIZATION;
D O I
10.1007/s11999-009-1011-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
During limb lengthening over an intramedullary nail, decisions regarding external fixator removal and weightbearing depend on the amount of callus seen at the lengthening area on radiographs. However, this method is subjective and objective evaluation of the amount of callus likely would minimize nail or interlocking screw breakage and refracture after fixator removal. We asked how many cortices with full corticalization of the newly formed bone at the lengthening area are needed to allow fixator removal and full weightbearing and how to radiographically determine the stage of corticalization. We retrospectively reviewed 17 patients (34 lengthenings) who underwent bilateral tibial lengthenings over an intramedullary nail. The average gain in length was 7.2 +/- A 3.4 cm. We determined the pixel value ratio (ratio of pixel value of regenerate versus the mean pixel value of adjacent bone) of the lengthened area on radiographs. There were no nail or screw breakage and refracture. Partial weightbearing with crutches was permitted when the pixel value ratio was 1 in two cortices and full weightbearing without crutches was permitted when the pixel value ratio was 1 in three cortices. The pixel value ratio on radiographs can be an objective parameter for callus measurement and may provide guidelines for the timing of external fixator removal. We cannot determine from our limited data the minimum pixel value in how many cortices would suggest safe removal, but we can say our criteria were not associated with subsequent refracture.
引用
收藏
页码:3321 / 3326
页数:6
相关论文
共 29 条
[1]
AQUERRETA JD, 1994, INT ORTHOP, V18, P299
[2]
CATAGNI M, 1991, OPERATIVE PRINCIPLES, V5, P53
[3]
MINERAL AND MATRIX CONTRIBUTIONS TO RIGIDITY IN FRACTURE-HEALING [J].
CHAKKALAKAL, DA ;
LIPPIELLO, L ;
WILSON, RF ;
SHINDELL, R ;
CONNOLLY, JF .
JOURNAL OF BIOMECHANICS, 1990, 23 (05) :425-434
[4]
De Backer A I, 2004, JBR-BTR, V87, P234
[5]
DEBASTIANI G, 1987, J PEDIATR ORTHOPED, V7, P129
[6]
Radiographic assessment of bone formation in tibia during distraction osteogenesis [J].
Donnan, LT ;
Saleh, M ;
Rigby, AS ;
McAndrew, A .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2002, 22 (05) :645-651
[7]
NEW BONE-FORMATION DURING LEG LENGTHENING - EVALUATED BY DUAL ENERGY X-RAY ABSORPTIOMETRY [J].
EYRES, KS ;
BELL, MJ ;
KANIS, JA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (01) :96-106
[8]
METHODS OF ASSESSING NEW BONE-FORMATION DURING LIMB LENGTHENING - ULTRASONOGRAPHY, DUAL-ENERGY X-RAY ABSORPTIOMETRY AND RADIOGRAPHY COMPARED [J].
EYRES, KS ;
BELL, MJ ;
KANIS, JA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03) :358-364
[9]
FISCHGRUND J, 1994, CLIN ORTHOP RELAT R, P31
[10]
Quantitative assessment of mineralization in distraction osteogenesis [J].
Hazra, Sunit ;
Song, Hae-Ryong ;
Biswal, Sandeep ;
Lee, Suk-Ha ;
Lee, Seok Hyun ;
Jang, Ki-Mo ;
Modi, Hitesh N. .
SKELETAL RADIOLOGY, 2008, 37 (09) :843-847