An assessment of the use of Implanon® in three community services

被引:20
作者
Smith, A [1 ]
Reuter, S
机构
[1] Saltergate Hlth Ctr, N Derbyshire Contracept & Sexual Hlth Serv, Derby S40 1SX, England
[2] Cent Nottinghamshire Family Planning Serv, Mansfield, England
[3] Doncaster Family Planning Serv, Doncaster, England
关键词
D O I
10.1783/147118902101196540
中图分类号
D669 [社会生活与社会问题]; C913 [社会生活与社会问题];
学科分类号
1204 ;
摘要
Aims. The aims of the study were three fold, namely to assess continuation rates with Implanon(R) fitted in clients from three contraception and sexual health services; to identify factors associated with early removal of Implanon(R); and to assess clinician compliance with recommended practice in counselling and insertion Methods. Retrospective review of client records, and comparison with audit criteria. Postal survey. Main findings. One hundred and ninety women had Implanon(R) inserted in the study period. Continuation rates were between 84% and 88% at 6 months and 67% and 78% at 12 months. There were no pregnancies or procedure complications. The main reasons for removal were identified as intolerance of recognised side effects or a change of mind about wanting contraception. Younger women were more likely to have the device removed early. There was evidence of excellent or good recording of many criteria for best practice in counselling and insertion. The assessment highlighted certain issues around counselling and insertion that services needed to consider further: Conclusions. The three services have been reassured that they are providing a good standard of care to clients requesting Implanon(R) and that their 'real life' 6- and 12-month continuation rates are reasonable.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 14 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]   Nonmenstrual adverse events during use of implantable contraceptives for women: data from clinical trials [J].
Brache, V ;
Faundes, A ;
Alvarez, F ;
Cochon, L .
CONTRACEPTION, 2002, 65 (01) :63-74
[3]  
COX DR, 1972, J R STAT SOC B, V34, P187
[4]  
Croxatto H B, 2000, Eur J Contracept Reprod Health Care, V5 Suppl 2, P21
[5]   A multicentre efficacy and safety study of the single contraceptive implant Implanon® [J].
Croxatto, HB ;
Urbancsek, J ;
Massai, R ;
Bennink, HC ;
van Beek, A .
HUMAN REPRODUCTION, 1999, 14 (04) :976-981
[6]   RETRACTED: The pharmacodynamics and efficacy of Implanon® - An overview of the data (Retracted Article) [J].
Croxatto, HB ;
Mäkäräinen, L .
CONTRACEPTION, 1998, 58 (06) :91S-97S
[7]  
Edwards J E, 1999, Br J Fam Plann, V24, P3
[8]   Implantable contraceptives for women: effectiveness, discontinuation rates, return of fertility, and outcome of pregnancies [J].
Glasier, A .
CONTRACEPTION, 2002, 65 (01) :29-37
[9]   Vaginal bleeding disturbances and implantable contraceptives [J].
Hickey, M ;
d'Arcangues, C .
CONTRACEPTION, 2002, 65 (01) :75-84
[10]   RETRACTED: Insertion and removal of Implanon® (Retracted Article) [J].
Mascarenhas, L .
CONTRACEPTION, 1998, 58 (06) :79S-83S