Deformation and Fracture of Mtwo Rotary Nickel-Titanium Instruments After Clinical Use

被引:41
作者
Inan, Ugur
Gonulol, Nihan
机构
[1] Ondokuz Mayis Univ, Dept Restorat Dent, Samsun, Turkey
[2] Ondokuz Mayis Univ, Dept Endodont, Samsun, Turkey
关键词
Clinical use; nickel-titanium; fracture; Mtwo; CYCLIC FATIGUE RESISTANCE; ENDODONTIC INSTRUMENTS; PROTAPER; DEFECTS; PROFILE; SYSTEMS; FAILURE; TORQUE; FILES;
D O I
10.1016/j.joen.2009.06.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: In recent years, a number of rotary nickel titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system. Although the NiTi instruments are more flexible than the stainless steel files, the main problem with the rotary NiTi instruments is the failure of the instruments. The aim of this study was to evaluate the deformation and fracture rate of Mtwo rotary nickel-titanium instruments (VDW, Munich, Germany) discarded after routine clinical use. Methods: A total of 593 Mtwo rotary NiTi instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, and then all the files were evaluated under a stereomicroscope for defects such as unwinding, curving, or bending and fracture. The fracture faces of separated files were also evaluated under a scanning electron microscope. The data were analyzed using a chi-square and z test. Results: A percentage of all files (25.80%) showed defects, and the major defect was fracture (16.02%). The most frequently fractured file was #10.04 (30.39%). Deformations without fracture were mostly observed on #15.05 files (25.47%). Conclusions: A higher rate of deformation was observed for #10.04 and #15.05 files. Therefore, these files should be considered as single-use instruments. Because cyclic fatigue was the cause of 71.58% of the instrument fractures, it is also important not to exceed the maximum number of usage recommended by the manufacturer and discard the instruments on a regular basis. (J Endod 2009,35:1396-1399)
引用
收藏
页码:1396 / 1399
页数:4
相关论文
共 27 条
[21]  
Tripi TR, 2001, J ENDODONT, V27, P782
[22]   Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments [J].
Ullmann, CJ ;
Peters, OA .
JOURNAL OF ENDODONTICS, 2005, 31 (03) :183-186
[23]  
Vieira EP, 2008, INT ENDOD J, V41, P163
[24]   Modes of failure of ProTaper nickel-titanium rotary instruments after clinical use [J].
Wei, Xi ;
Ling, Junqi ;
Jiang, Jin ;
Huang, Xiangya ;
Liu, Lu .
JOURNAL OF ENDODONTICS, 2007, 33 (03) :276-279
[25]   Separation incidence of protaper rotary instruments: A large cohort clinical evaluation [J].
Wolcott, Susan ;
Wolcott, James ;
Ishley, David ;
Kennedy, Wade ;
Johnson, Scott ;
Minnich, Scott ;
Meyers, John .
JOURNAL OF ENDODONTICS, 2006, 32 (12) :1139-1141
[26]   Cyclic fatigue of Profile rotary instruments after clinical use [J].
Yared, GM ;
Dagher, FEB ;
Machtou, P .
INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (03) :204-207
[27]   Influence of rotational speed, torque and operator's proficiency on ProFile failures [J].
Yared, GM ;
Dagher, FEB ;
Machtou, P .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (01) :47-53