Determination of a series of quinolones in pig plasma using solid-phase extraction and liquid chromatography coupled with mass spectrometric detection -: Application to pharmacokinetic studies

被引:44
作者
Garces, A.
Zerzanova, A.
Kucera, R.
Barron, D.
Barbosa, J.
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
[2] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Pharmaceut Chem & Drug Control, Hradec Kralove 50005, Czech Republic
关键词
quinolones; plasma analysis; solid-phase extraction; liquid chromatography; mass spectrometry;
D O I
10.1016/j.chroma.2006.09.082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and sensitive liquid chromatography (LC) method was developed for the simultaneous determination of eight quinolones in pig plasma samples. The following two methods of detection were used: ultraviolet (UV) and mass spectrometry with electrospray ionization (ESI/MS). Sample preparation consisted of solid-phase extraction (SPE) on Strata X cartridges prior to the analysis by LC/UV or LC/ESI/MS. The recovery, linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy of the method were evaluated using spiked pig plasma samples. The suitability of the method for pharmacokinetic studies was evaluated by determining the concentrations of enrofloxacin (ENR) and ciprofloxacin (CIP) also in pig plasma, after administration of 200 mg of enrofloxacin per kilogram of fodder during 5 consecutive days. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 35 条
  • [1] Quinolones
    Alós, JI
    [J]. ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2003, 21 (05): : 261 - 268
  • [2] Determination of fluoroquinolones in chicken tissues by LC-coupled electrospray ionisation and atmospheric pressure chemical ionisation
    Bailac, S
    Barrón, D
    Sanz-Nebot, V
    Barbosa, J
    [J]. JOURNAL OF SEPARATION SCIENCE, 2006, 29 (01) : 131 - 136
  • [3] Determination of quinolones in chicken tissues by liquid chromatography with ultraviolet absorbance detection
    Bailac, S
    Ballesteros, O
    Jiménez-Lozano, E
    Barrón, D
    Sanz-Nebot, V
    Navalón, A
    Vílchez, JL
    Barbosa, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) : 145 - 151
  • [4] ASSIGNMENT OF REFERENCE PH-VALUES TO PRIMARY STANDARD BUFFER SOLUTIONS FOR STANDARDIZATION OF POTENTIOMETRIC SENSORS IN ACETONITRILE-WATER MIXTURES
    BARBOSA, J
    SANZNEBOT, V
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 353 (02): : 148 - 155
  • [5] The application of factor analysis to solvatochromic parameters and pHs values for the standardization of potentiometric sensors in mobile phases used in liquid chromatography
    Barbosa, J
    Marqués, I
    Barrón, D
    Sanz-Nebot, V
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) : 543 - 549
  • [6] Methods of analysis olf 4-quinolone antibacterials
    Belal, F
    Al-Majed, AA
    Al-Obaid, AM
    [J]. TALANTA, 1999, 50 (04) : 765 - 786
  • [7] Analysis of fluoroquinolones in biological fluids by high-performance liquid chromatography
    Carlucci, G
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 343 - 367
  • [8] *COMM EUR COMM, 1990, DIAR OF COM EUR DO L, V224, P991
  • [9] Analysis of antibiotics by capillary electrophoresis
    Flurer, CL
    [J]. ELECTROPHORESIS, 2003, 24 (22-23) : 4116 - 4127
  • [10] Simultaneous determination of difloxacin and its primary metabolite sarafloxacin in rabbit plasma
    Garcia, MA
    Solans, C
    Aramayona, JJ
    Rueda, S
    Bregante, MA
    [J]. CHROMATOGRAPHIA, 2000, 51 (7-8) : 487 - 490