A novel potentiometric membrane sensor for determination of Co2+ based on 5-amino-3-methylisothiazole

被引:28
作者
Kumar Singh, Ashok [1 ]
Mehtab, Sameena [1 ]
Saxena, Puja [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
potentiometry; Co (II) ion-selective electrode; 5-amino-3-methylisothiazole; poly(vinylchloride)membrane;
D O I
10.1016/j.snb.2006.02.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new poly(vinylchloride) (PVC) membrane electrode for trace level determination of Co2+ ions has been developed based on 5-amino-3-methylisothiazole as an ionophore, o-nitrophenyloctylether as a plasticizer and oleic acid (OA) as a good lipophilic additive. The electrode exhibits a Nernstian slope of 29.5 +/- 0.2 mV/decade in a linear range of 1.0 x 10(-1) to 6.3 x 10(-7) M for Co2+ ions. The detection limit of this electrode is 3.9 x 10(-7) M. It has a fast response time of 12 s and can be used for a period of 4 months without any divergence in potentials. The proposed electrode reveals a good selectivity for Co (II) over a wide variety of other tested cations and could be used in the pH range 3.3-9.0. The electrode was successfully applied as an indicator electrode for the potentiometric titration of cobalt ions with EDTA as well as for the direct determination of Co (H) in real samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:455 / 461
页数:7
相关论文
共 44 条
[1]   A new cerium (III)-selective membrane electrode based on 2-aminobenzothiazole [J].
Akhond, M ;
Najafi, MB ;
Tashkhourian, J .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (2-3) :410-415
[2]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[3]   NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF TOTAL CALCIUM IN BLOOD-SERUM [J].
ANKER, P ;
WIELAND, E ;
AMMANN, D ;
DOHNER, RE ;
ASPER, R ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :1970-1974
[4]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[5]  
AWASTHI SP, 1991, J ELECTROCHEM SOC IN, V40, P23
[6]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[7]  
BEHRENS NB, 1991, POLYHEDRON, V10, P1333
[8]  
BRZOZKA Z, 1988, ANALYST, V113, P891
[9]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[10]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687