Instrumental neutron activation analysis (INAA) and inductively coupled plasma/mass spectrometry (ICP-MS) for trace element biomonitoring using mosses

被引:12
作者
Ayrault, S [1 ]
Galsomiès, L
Amblard, G
Sciarretta, MD
Bonhomme, P
Gaudry, A
机构
[1] CEA Saclay, CNRS, CEA, Lab Pierre Sue, F-91191 Gif Sur Yvette, France
[2] Agence Environm & maitrise Energie, Dept Air, F-75737 Paris, France
[3] CEA, CNRS, Lab Sci Climat & Environm, F-91198 Gif Sur Yvette, France
关键词
biomonitoring; mosses; trace elements; elemental analysis; INAA; ICP-MS;
D O I
10.1080/0306731021000014994
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two analytical methods - instrumental neutron activation analysis (INAA) and inductively coupled plasma mass spectrometry (ICP-MS) - were used for the trace element analysis of naturally growing mosses for a heavy metal biomonitoring survey. The techniques were applied to reference mosses to evaluate the feasibility, analytical variability, detection limits and accuracy. These parameters were evaluated using 563 mosses sampled in the 1996 French survey. All the elements of interest in the European program "Atmospheric Heavy Metal Deposition in Europe - estimation based on moss analysis" (As, Cd, Cr, Cu, Fe, Hg, Pb, Ni, V, Zn) were able to be determined by ICP-MS. INAA appeared suitable for the determination of As, Cr, Fe, Hg, V and Zn. The Cd, Cu, Ni and Pb concentrations determined by ICP-MS were preferred to the INAA results, because of increased feasibility or accuracy. The results provided by both methods on the French mosses were statistically compared for 14 elements. Significant linear correlation appeared for: Ba, Ce, Cs, La, Rb, Sm, Th and V. Among these eight elements, Ba, Cs, La and Sm concentrations determined by both methods exhibited a strong statistical similarity. The correlations obtained for As, Eu, Fe and Sb were not as strong and no correlation at all was observed for Co and Cr. These differences were attributed to instrumental factors (e.g. spectral interference occurred for both methods) or due to the sample preparation prior to ICP-MS. The consequences of such results on the regional trend evaluation of atmospheric heavy metal deposition were discussed.
引用
收藏
页码:463 / 473
页数:11
相关论文
共 22 条
[11]  
Markert B, 1993, Plants as biomonitors: indicators for heavy metals in the terrestrial environment
[12]  
MARKERT B, 1996, INSTRUMENTAL ANAL PL, P111
[13]  
Martin M. H., 1982, BIOL MONITORING HEAV
[14]   Ko-LABSUE: A quasi non-dependent data format package for K-0-quantification [J].
Piccot, D ;
Deschamps, C ;
Delmas, R ;
Revel, G .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (02) :263-269
[15]   Comparative use of INAA and ICP-MS methods for environmental studies [J].
Revel, G ;
Ayrault, S .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 244 (01) :73-80
[16]  
RUHLING A, 1968, Botaniska Notiser, V121, P321
[17]  
RUHLING A, 1998, NORD, V15
[18]   Comparison of 14 MeV-NAA, k0-NAA and ED-XRF for air pollution bio-monitoring [J].
Senhou, A ;
Chouak, A ;
Cherkaoui, R ;
Lferde, M ;
Elyahyaoui, A ;
El Khoukhi, T ;
Bounakhla, M ;
Embarche, K ;
Bertho, X ;
Gaudry, A ;
Ayrault, S ;
Piccot, D .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 253 (02) :247-252
[19]   ATMOSPHERIC DEPOSITION OF TRACE-ELEMENTS IN NORWAY - TEMPORAL AND SPATIAL TRENDS STUDIED BY MOSS ANALYSIS [J].
STEINNES, E ;
HANSSEN, JE ;
RAMBAEK, JP ;
VOGT, NB .
WATER AIR AND SOIL POLLUTION, 1994, 74 (1-2) :121-140
[20]   Reference materials for large-scale metal deposition surveys [J].
Steinnes, E ;
Ruhling, A ;
Lippo, H ;
Makinen, A .
ACCREDITATION AND QUALITY ASSURANCE, 1997, 2 (05) :243-249