Reliability of repeated sprint exercise in non-motorised treadmill ergometry

被引:41
作者
Hughes, M. G. [1 ]
Doherty, M. [1 ]
Tong, R. J. [1 ]
Reilly, T. [1 ]
Cable, N. T. [1 ]
机构
[1] Univ Wales Inst, Sch Sport PE & Recreat, Cardiff CF23 6XD, Wales
关键词
reproducibility; running; speed; force;
D O I
10.1055/s-2006-923791
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Although repeated sprint tests are relatively common, there have been few investigations of repeated sprint exercise using non-motorised treadmill ergometry. The purpose of this study was to determine the reliability of a repeated sprint procedure using this apparatus. Ten healthy, active males, performed three repeated sprint tests (six repetitions of 6 s sprints with 30 s recovery) on three separate occasions. Performance as determined by maximal speed, average force production, and fatigue were compared across the three trials. Maximal speed and average force were not significantly different between visits (p < 0.05) and a variety of reliability measures suggested good agreement (e.g., coefficient of variations no more than 5%). The fatigue indices for maximal speed and for average force were generally less reliable (coefficients of variation around 30% in both cases). In conclusion, measures of performance (maximal speed and average force) can provide reliable results in a repeated sprint protocol but the reliability of fatigue measures appears to be low.
引用
收藏
页码:900 / 904
页数:5
相关论文
共 25 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]   Induced metabolic alkalosis affects muscle metabolism and repeated-sprint ability [J].
Bishop, D ;
Edge, J ;
Davis, C ;
Goodman, C .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05) :807-813
[3]  
Bishop D, 2004, J SPORT MED PHYS FIT, V44, P1
[4]   The validity of a repeated sprint ability test [J].
Bishop, D ;
Spencer, M ;
Duffield, R ;
Lawrence, S .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2001, 4 (01) :19-29
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Reliability of power output during intermittent high-intensity cycling [J].
Capriotti, PV ;
Sherman, WM ;
Lamb, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (06) :913-915
[7]  
Cheetham M E, 1985, Br J Sports Med, V19, P81
[8]  
Dawson B, 1991, SPORTS COACH, V14, P12
[9]  
Dawson B., 1993, Australian Journal of Science and Medicine in Sport, V25, P88
[10]  
Fitzsimmons M, 1993, AUST J SCI MED SPORT, V25, P82