Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils

被引:28
作者
Alecci, M
Collins, CM
Wilson, J
Liu, WZ
Smith, MB
Jezzard, P [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, FMRIB Ctr, Dept Clin Neurol, Oxford OX3 9DU, England
[2] Penn State Coll Med, Dept Radiol, Ctr NMR Res, Hershey, PA USA
[3] Univ Aquila, Dipartimento Sci & Tecnol Biomed, INFM, Laquila, Italy
关键词
high-field MRI; RF mapping; birdcage coil; endcap; human brain;
D O I
10.1002/mrm.10352
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of detached endcaps for 3 T birdcage coils was investigated both theoretically and experimentally. Finite difference time domain analysis along With workbench and MRI techniques, were used to map the radiofrequency (RF) B-1 distribution along the coil axis with and without an endcap. Without an endcap the measured B-1 Value at the service end of the birdcage was only 45% of the value at the coil's center. This was improved to 85% with, a detached endcap of maximum achievable diameter (375 mm), positioned 4 mm from the RF shield. The B-1 field distribution on the patient side of the coil was unaffected by the presence of the endcap. The dependence of the B-1 distribution as a function of endcap diameter was also investigated. Surprisingly, simulations and experiments show that there is an optimum ratio of endcap-to-birdcage coil diameter (approximate to1.08) that gives the best B-1 homogeneity. In the human head the optimized endcap, positioned 16 mm from the RF shield, improves the MRI signal amplitude from 55% to 85% of maximum toward the service end. This novel endcap design is easy to implement with existing birdcage coils, and could prove useful when flexibility in access to the RF coil is required. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 24 条
[1]   Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator [J].
Alecci, M ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :404-407
[2]   Radio frequency magnetic field mapping of a 3 tesla birdcage coil: Experimental and theoretical dependence on sample properties [J].
Alecci, M ;
Collins, CM ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :379-385
[3]  
ALECCI M, 2002, P 10 ANN M ISMRM HON, P916
[4]  
ALECCI M, 2001, P 9 ANN M ISMRM GLAS, P1091
[5]  
ALECCI M, 1999, BRIT CHAPT ISMRM LON
[6]  
Barberi EA, 2000, MAGNET RESON MED, V43, P284, DOI 10.1002/(SICI)1522-2594(200002)43:2<284::AID-MRM16>3.0.CO
[7]  
2-C
[8]  
CHEN J, 1998, P 6 ANN M ISMRM SYDN, P2041
[9]   Compensating for B1 inhomogeneity using active transmit power modulation [J].
Clare, S ;
Alecci, M ;
Jezzard, P .
MAGNETIC RESONANCE IMAGING, 2001, 19 (10) :1349-1352
[10]   SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil [J].
Collins, CM ;
Li, SZ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :847-856