Implantation of paclitaxel-eluting stents in saphenous vein grafts:: clinical and angiographic follow-up results from a multicentre study

被引:42
作者
Hoffmann, Rainer
Pohl, Tilmann
Koester, Ralf
Blindt, Ruediger
Boeckstegers, Peter
Heitzer, Thomas
机构
[1] Univ Aachen, Rhein Westfal TH Aachen, Med Clin 1, D-52057 Aachen, Germany
[2] Univ Grosshadern Munich, Med Clin, Munich, Germany
[3] Univ Hamburg, Med Clin 2, Hamburg, Germany
关键词
D O I
10.1136/hrt.2006.094722
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To define the clinical and angiographic follow-up results after implantation of paclitaxel-eluting stents (PESs) in stenotic saphenous vein grafts (SVGs). Design: Prospective multicentre study. Comparison with a control group. Methods: 60 consecutive patients with 65 lesions located in 65 SVGs (mean (SD) age of vein grafts 11.3 (5.7) years) treated with PES (V-Flex Plus, 2.7 mg/mm(2) paclitaxel, Cook) and 60 patients with 60 SVG lesions treated with bare metal stent (BMS) were included. Lesions had to be < 20 mm in length and in grafts of 2.75-3.5 mm diameter. The 6 month angiographic follow-up was obtained on 51 lesions (79%) of the PES group and on 51 lesions (85%) of the BMS group. Results: Baseline clinical and angiographic characteristics were comparable between both groups. At angiographic follow-up, three vein grafts in the PES group and five vein grafts in the BMS group were occluded. In-stent late lumen loss was lower in PES than in BMS (0.61 (0.81) vs 1.06 (0.72) mm, respectively; p = 0.021). In-stent binary restenosis rates were 12% vs 33%, respectively, (p = 0.012). Linear regression analysis showed BMS to be the only factor with an effect on late lumen loss (p = 0.011). Target-vessel failure rates were 18% in the PES group and 41% in the BMS group (p = 0.019), whereas major adverse cardiac event (MACE) rates at 180 days were 15% and 37%, respectively (p = 0.014). Conclusions: Implantation of non-polymer-based PES in SVG lesions is associated with a lower late lumen loss and restenosis rate than those of BMS. There remains a substantial target-vessel failure rate and MACE rate even at 6 months owing to graft occlusion or new lesions in the graft.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 22 条
[1]   Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts [J].
Baim, DS ;
Wahr, D ;
George, B ;
Leon, MB ;
Greenberg, J ;
Cutlip, DE ;
Kaya, U ;
Popma, JJ ;
Ho, KKL ;
Kuntz, RE .
CIRCULATION, 2002, 105 (11) :1285-1290
[2]   Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention [J].
Chu, WW ;
Rha, SW ;
Kuchulakanti, PK ;
Cheneau, E ;
Torguson, R ;
Pinnow, E ;
Alexieva-Fournadjiev, J ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Lindsay, J ;
Waksman, R .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (01) :34-37
[3]   Vessel size and long-term outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Neumann, FJ ;
Hadamitzky, M ;
Dirschinger, J ;
Schömig, A .
CIRCULATION, 1998, 98 (18) :1875-1880
[4]   CORONARY-BYPASS GRAFT FATE - LONG-TERM ANGIOGRAPHIC STUDY [J].
FITZGIBBON, GM ;
LEACH, AJ ;
KAFKA, HP ;
KEON, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (05) :1075-1080
[5]   Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years [J].
FitzGibbon, GM ;
Kafka, HP ;
Leach, AJ ;
Keon, WJ ;
Hooper, GD ;
Burton, JR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (03) :616-626
[6]   Treatment of saphenous vein graft lesions with drug-eluting stents - Immediate and midterm outcome [J].
Ge, L ;
Iakovou, I ;
Sangiorgi, GM ;
Chieffo, A ;
Melzi, G ;
Cosgrave, J ;
Montorfano, M ;
Michev, I ;
Airoldi, F ;
Carlino, M ;
Corvaja, N ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) :989-994
[7]   Inhibition of restenosis with a paclitaxel-eluting, polymer-free coronary stent - The European evaLUation of pacliTaxel Eluting Stent (ELUTES) trial [J].
Gershlick, A ;
De Scheerder, I ;
Chevalier, B ;
Stephens-Lloyd, A ;
Camenzind, E ;
Vrints, C ;
Reifart, N ;
Missault, L ;
Goy, JJ ;
Brinker, JA ;
Raizner, AE ;
Urban, P ;
Heldman, AW .
CIRCULATION, 2004, 109 (04) :487-493
[8]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[9]   Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents [J].
Kastrati, A ;
Dibra, A ;
Mehilli, J ;
Mayer, S ;
Pinieck, S ;
Pache, J ;
Dirschinger, J ;
Schöming, A .
CIRCULATION, 2006, 113 (19) :2293-2300
[10]   Non-polymer-based paclitaxel-coated coronary stents for the treatment of patients with de novo coronary lesions - Angiographic follow-up of the DELIVER clinical trial [J].
Lansky, AJ ;
Costa, RA ;
Mintz, GS ;
Tsuchiya, Y ;
Midei, M ;
Cox, DA ;
O'Shaughnessy, C ;
Applegate, RA ;
Cannon, LA ;
Mooney, M ;
Farah, A ;
Tannenbaum, MA ;
Yakubov, S ;
Kereiakes, DJ ;
Wong, SC ;
Kaplan, B ;
Cristea, E ;
Stone, GW ;
Leon, MB ;
Knopf, WD ;
O'Neill, WW .
CIRCULATION, 2004, 109 (16) :1948-1954