In Vivo Carbon-13 Dynamic MRS and MRSI of Normal and Fasted Rat Liver with Hyperpolarized 13C-Pyruvate

被引:55
作者
Hu, Simon [1 ,2 ]
Chen, Albert P. [3 ]
Zierhut, Matthew L. [1 ,2 ]
Bok, Robert [1 ]
Yen, Yi-Fen [3 ]
Schroeder, Marie A. [4 ]
Hurd, Ralph E. [3 ]
Nelson, Sarah J. [1 ,2 ]
Kurhanewicz, John [1 ,2 ]
Vigneron, Daniel B. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94158 USA
[2] UCSF & UCB Joint Grad Grp Bioengn, Berkeley, CA USA
[3] GE Healthcare, Menlo Pk, CA USA
[4] Univ Oxford, Dept Physiol, Oxford, England
关键词
Hyperpolarized carbon-13; Dynamic nuclear polarization (DNP); Magnetic resonance spectroscopy/spectroscopic imaging; Fasted liver; Alanine aminotransferase; TRICARBOXYLIC-ACID CYCLE; GLUCONEOGENESIS; DEHYDROGENASE; SPECTROSCOPY; PYRUVATE; ALANINE; DESIGN; FLUX; 3T;
D O I
10.1007/s11307-009-0218-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The use of in vivo C-13 nuclear magnetic resonance spectroscopy in probing metabolic pathways to study normal metabolism and characterize disease physiology has been limited by its low sensitivity. However, recent technological advances have enabled greater than 50,000-fold enhancement of liquid-state polarization of metabolically active C-13 substrates, allowing for rapid assessment of C-13 metabolism in vivo. The present study applied hyperpolarized C-13 magnetic resonance spectroscopy to the investigation of liver metabolism, demonstrating for the first time the feasibility of applying this technology to detect differences in liver metabolic states. Procedures: [1-C-13] pyruvate was hyperpolarized with a dynamic nuclear polarization instrument and injected into normal and fasted rats. The uptake of pyruvate and its conversion to the metabolic products lactate and alanine were observed with slice-localized dynamic magnetic resonance spectroscopy and 3D magnetic resonance spectroscopic imaging (3D-MRSI). Results: Significant differences in lactate to alanine ratio (P<0.01) between normal and fasted rat liver slice dynamic spectra were observed. 3D-MRSI localized to the fasted livers demonstrated significantly decreased C-13-alanine levels (P<0.01) compared to normal. Conclusions: This study presents the initial demonstration of characterizing metabolic state differences in the liver with hyperpolarized C-13 spectroscopy and shows the ability to detect physiological perturbations in alanine aminotransferase activity, which is an encouraging result for future liver disease investigations with hyperpolarized magnetic resonance technology.
引用
收藏
页码:399 / 407
页数:9
相关论文
共 33 条
[1]   Increase in signal-to-noise ratio of &gt;10,000 times in liquid-state NMR [J].
Ardenkjaer-Larsen, JH ;
Fridlund, B ;
Gram, A ;
Hansson, G ;
Hansson, L ;
Lerche, MH ;
Servin, R ;
Thaning, M ;
Golman, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (18) :10158-10163
[2]   MAXIMUM ACTIVITIES OF KEY ENZYMES OF GLYCOLYSIS, GLUTAMINOLYSIS, PENTOSE-PHOSPHATE PATHWAY AND TRICARBOXYLIC-ACID CYCLE IN NORMAL, NEOPLASTIC AND SUPPRESSED CELLS [J].
BOARD, M ;
HUMM, S ;
NEWSHOLME, EA .
BIOCHEMICAL JOURNAL, 1990, 265 (02) :503-509
[3]   Role of mitochondrial lactate dehydrogenase and lactate oxidation in the intracellular lactate shuttle [J].
Brooks, GA ;
Dubouchaud, H ;
Brown, M ;
Sicurello, JP ;
Butz, CE .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (03) :1129-1134
[4]   Feasibility of using hyperpolarized [1-13C]lactate as a substrate for in vivo metabolic 13C MRSI studies [J].
Chen, Albert P. ;
Kurhanewicz, John ;
Bok, Robert ;
Xu, Duan ;
Joun, David ;
Zhang, Vickie ;
Nelson, Sarah J. ;
Hurd, Ralph E. ;
Vigneron, Daniel B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (06) :721-726
[5]   Hyperpolarized c-13 spectroscopic imaging of the TRAMP mouse at 3T - Initial experience [J].
Chen, Albert P. ;
Albers, Mark J. ;
Cunningham, Charles H. ;
Kohler, Susan J. ;
Yen, Yi-Fen ;
Hurd, Ralph E. ;
Tropp, James ;
Bok, Robert ;
Pauly, John M. ;
Nelson, Sarah J. ;
Kurhanewicz, John ;
Vigneron, Daniel B. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) :1099-1106
[8]   Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging [J].
Cunningham, CH ;
Vigneron, DB ;
Chen, AP ;
Xu, D ;
Nelson, SJ ;
Hurd, RE ;
Kelley, DA ;
Pauly, JM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1286-1289
[9]   Double spin-echo sequence for rapid spectroscopic imaging of hyperpolarized 13C [J].
Cunningham, Charles H. ;
Chen, Albert P. ;
Albers, Mark J. ;
Kurhanewicz, John ;
Hurd, Ralph E. ;
Yen, Yi-Fen ;
Pauly, John M. ;
Nelson, Sarah J. ;
Vigneron, Daniel B. .
JOURNAL OF MAGNETIC RESONANCE, 2007, 187 (02) :357-362
[10]   Detecting tumor response to treatment using hyperpolarized 13C magnetic resonance imaging and spectroscopy (vol 13, pg 1382, 2007) [J].
Day, Sam E. ;
Kettunen, Mikko I. ;
Gallagher, Ferdia A. ;
Hu, De-En ;
Lerche, Mathilde ;
Wolber, Jan ;
Golman, Klaes ;
Ardenkjaer-Larsen, Jan Henrik ;
Brindle, Kevin M. .
NATURE MEDICINE, 2007, 13 (12) :1521-1521