Solid phase microextraction as sample introduction technique for radio frequency glow discharge mass spectrometry

被引:19
作者
Gorecki, T
Belkin, M
Caruso, J
Pawliszyn, J
机构
[1] UNIV WATERLOO,DEPT CHEM,WATERLOO,ON N2L 3G1,CANADA
[2] UNIV WATERLOO,WATERLOO CTR GROUNDWATER RES,WATERLOO,ON N2L 3G1,CANADA
[3] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
来源
ANALYTICAL COMMUNICATIONS | 1997年 / 34卷 / 10期
关键词
D O I
10.1039/a704264g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid phase microextraction (SPME) was used for sampling and sample introduction directly to a mass spectrometer with an rf glow discharge ion source (rf GDMS). Aqueous solutions of tetraethyllead (TEL) were analyzed at 200 ppt concentration level. TEL was extracted by the SPME fibre from the headspace of vigorously stirred samples. The analytes were then flash desorbed from the fibre in a dedicated injector connected directly to the rf glow discharge ion source of a mass spectrometer. Flash desorption resulted in narrow peaks, with very good signal to noise ratios. The spectra obtained could be used for both quantification and compound identification based on the molecular fragment ions produced. TEL and tetramethyltin were also introduced together to the rf GDMS system. Both compounds produced very good spectra that could be used for quantification.
引用
收藏
页码:275 / 277
页数:3
相关论文
共 33 条
[1]   EFFECT OF DISCHARGE CONDITIONS ON THE SPUTTERING AND SPATIAL-DISTRIBUTION OF ATOMS IN A RADIOFREQUENCY GLOW-DISCHARGE ATOMIZER FOR ATOMIC-ABSORPTION SPECTROMETRY [J].
ABSALAN, G ;
CHAKRABARTI, CL ;
HUTTON, JC ;
BACK, MH ;
LAZIK, C ;
MARCUS, RK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (01) :45-52
[2]  
ARTHUR CL, 1992, HRC-J HIGH RES CHROM, V15, P741
[3]   ANALYSIS OF SUBSTITUTED BENZENE COMPOUNDS IN GROUNDWATER USING SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
MOTLAGH, S ;
LIM, M ;
POTTER, DW ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (05) :979-983
[4]  
BELKIN MA, 1997, IN PRESS J ANAL AT S, V12
[5]   PRELIMINARY-STUDY OF THE ROLE OF DISCHARGE CONDITIONS ON THE IN-DEPTH ANALYSIS OF CONDUCTING THIN-FILMS BY RADIOFREQUENCY GLOW-DISCHARGE OPTICAL-EMISSION SPECTROMETRY [J].
BORDELGARCIA, N ;
PEREIROGARCIA, R ;
FERNANDEZGARCIA, M ;
SANZMEDEL, A ;
HARVILLE, TR ;
MARCUS, RK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) :671-676
[6]   Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of alkylphenol ethoxylate surfactants in water [J].
BoydBoland, AA ;
Pawliszyn, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1521-1529
[7]   SOLID-PHASE MICROEXTRACTION OF NITROGEN-CONTAINING HERBICIDES [J].
BOYDBOLAND, AA ;
PAWLISZYN, JB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) :163-172
[8]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[9]   PARAMETER EVALUATION FOR THE ANALYSIS OF OXIDE-BASED SAMPLES WITH RADIO-FREQUENCY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DEGENDT, S ;
VANGRIEKEN, RE ;
OHORODNIK, SK ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1026-1033
[10]   DESIGN AND CHARACTERIZATION OF A RADIO-FREQUENCY-POWERED GLOW-DISCHARGE SOURCE FOR DOUBLE-FOCUSING MASS SPECTROMETERS [J].
DUCKWORTH, DC ;
DONOHUE, DL ;
SMITH, DH ;
LEWIS, TA ;
MARCUS, RK .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2478-2484